TypeD R29 CameraLink Triggering Guide 

 

Software setup

 

 

Make sure any old software for interfacing with the Camera is uninstalled (RxLive 2.8, 

TypeD 2.8 camera drivers, TypeCL 2.8 FrameGrabber drives, ConvCam 3, ConvCam 4)

 

 

Make sure that the newest version of the Euresys MultiCam software for your Euresys 

Grablink Full FrameGrabber is installed

 

 

Install the newest version of RxLive, CL Euresys FrameGrabber drivers and TypeD 

camera drivers

 

 

Install the RxCalibData for your camera

 

 

Connecting the camera

 

 

Connect the camera using the two supplied CameraLink cables

 

 

Make sure the cables are connecting the camera and the FrameGrabber in the right 

way:

 

 

Summary of Contents for R29

Page 1: ...p Make sure any old software for interfacing with the Camera is uninstalled RxLive 2 8 TypeD 2 8 camera drivers TypeCL 2 8 FrameGrabber drives ConvCam 3 ConvCam 4 Make sure that the newest version of the Euresys MultiCam software for your Euresys Grablink Full FrameGrabber is installed Install the newest version of RxLive CL Euresys FrameGrabber drivers and TypeD camera drivers Install the RxCalib...

Page 2: ...auenburgerstraße 116 D 24118 Kiel Germany www raytrix de The cables should connect the ports with the same numbers If the camera is not detected at all in RxLive the first step is to check the cables Connect the power supply cable to the camera ...

Page 3: ...era marked C in picture below The cable is wired to the connector as follows Connect a power supply with 10V 25V DC to pins 1 and 2 Connect the source of your trigger impulse to pin 5 The trigger source must have the same ground potential as pin 1 a connection from the negative or ground pin of the trigger source to pin 1 of the camera might be necessary A trigger impulse voltage of 10V is suffici...

Page 4: ...raytrix GmbH We sharpen your image Schauenburgerstraße 116 D 24118 Kiel Germany www raytrix de Configuration of RxLive Start RxLive Activate the External Trigger Checkbox in the camera control tab of RxLive ...

Page 5: ...he end of the first frame and the start of the second frame is approximately 30 microseconds The exposure time of the first frame can be controlled by using the Shtr value in RxLive to adjust the shutter time The exposure time of the second frame is fixed and can not be controlled in any way A timing diagram is shown in the next picture The exposure amount of light contributing to the image should...

Reviews: