Setup for external triggering

 

 

Use the triggering cable supplied by Raytrix and connect it to the Hirose connector of 
the camera (marked „C“ in picture below)

 

 

The cable is wired to the connector as follows:

 

 

 

 

 

Connect a power supply with 10V…25V DC to pins 1 and 2

 

 

Connect the source of your trigger impulse to pin 5

 

 

The trigger source must have the same ground potential as pin 1, a connection 
from the negative or ground pin of the trigger source to pin 1 of the camera might 
be necessary

 

 

A trigger impulse voltage of 10V is sufficient to trigger the camera

 

 

 

Summary of Contents for R29

Page 1: ...p Make sure any old software for interfacing with the Camera is uninstalled RxLive 2 8 TypeD 2 8 camera drivers TypeCL 2 8 FrameGrabber drives ConvCam 3 ConvCam 4 Make sure that the newest version of the Euresys MultiCam software for your Euresys Grablink Full FrameGrabber is installed Install the newest version of RxLive CL Euresys FrameGrabber drivers and TypeD camera drivers Install the RxCalib...

Page 2: ...auenburgerstraße 116 D 24118 Kiel Germany www raytrix de The cables should connect the ports with the same numbers If the camera is not detected at all in RxLive the first step is to check the cables Connect the power supply cable to the camera ...

Page 3: ...era marked C in picture below The cable is wired to the connector as follows Connect a power supply with 10V 25V DC to pins 1 and 2 Connect the source of your trigger impulse to pin 5 The trigger source must have the same ground potential as pin 1 a connection from the negative or ground pin of the trigger source to pin 1 of the camera might be necessary A trigger impulse voltage of 10V is suffici...

Page 4: ...raytrix GmbH We sharpen your image Schauenburgerstraße 116 D 24118 Kiel Germany www raytrix de Configuration of RxLive Start RxLive Activate the External Trigger Checkbox in the camera control tab of RxLive ...

Page 5: ...he end of the first frame and the start of the second frame is approximately 30 microseconds The exposure time of the first frame can be controlled by using the Shtr value in RxLive to adjust the shutter time The exposure time of the second frame is fixed and can not be controlled in any way A timing diagram is shown in the next picture The exposure amount of light contributing to the image should...

Reviews: