background image

1/20/2015 (3:46 PM) 
2034vx & 2034vxa v6.0.doc 

 

 

! NOTICE 

DO NOT add new abrasive to worn abrasive.  
Always replace worn abrasive with new abrasive 
using the following procedures.  Always wear 
respiratory protection for this procedure.

 

 

4.4.1.2

 

Remove the Blast Nozzle (T) from the Blast 

Hose (K).  Place the abrasive disposal bucket, with 
lid attached,  into the cabinet and close the door.  
Turn on the dust collector.  Place the nozzle of the 
blast hose into the abrasive disposal bucket. Set 
the Air Pressure Regulator Gauge (H) to 20 PSI by 
adjusting Air Pressure Regulator Knob (A). Turn 
off the Air Flow Valve (B).  Press the Foot Pedal 
(F) until the bucket is full or the pressure pot is 
empty.  Put worn abrasive in plastic bag and 
dispose of according to local regulations. Repeat 
as necessary until abrasive is completely emptied. 

 

 

 

4.4.2

 

Adding New Abrasive

 

4.4.3

 

With the dust collector on, place unopened 

50lb bag of abrasive into the cabinet.  Slit the side 
of the bag open allowing the abrasive to flow into 
the bottom of the cabinet.  Close the side door and 
empty the remainder of the bag using the front 
armhole access.  After the dust has cleared remove 
the bag from the cabinet.

 

 

4.5

 

Viewing Glass Replacement 

 

! WARNING 

Edges of glass can be sharp and cut through your 
skin.  Wear protective gloves when handling the 
glass. 

4.5.1.1

 

The window consists of two 12

"

 x 24

"

 panes 

of glass, the outer double safety laminate 
(replacement not required), and the inner 1/8

"

 

thick single strength glass. The inner single 
strength glass will get frosted over time and will 
impair visibility.

 

! NOTICE 

12

"

 x 24

"

 x 1/8

"

 thick single strength window glass 

can be purchased from a local glass retailer. 

 

 

 

4.5.1.2

 

To replace: loosen (but do not remove) the 

five window bracket screws on the bottom of the 
window and the four bracket screws on the top of 
the window. Carefully slide both panes of glass 
out to the right or left of the cabinet.

 

4.5.1.3

 

Replace the single strength glass pane and 

slide both back into the window brackets. Tighten 
five bottom bracket screws so that the bracket is 
firmly against the face of the cabinet. Tighten 4 
bracket screws on top until glass is slightly 
compressing the foam seal under the glass.  DO 
NOT over tighten these 4 screws.

 

 
4.6

 

Replacing FSV Sleeve (R)

 

! WARNING 

Disconnect air and depressurize pot before 
replacing the Tube Sleeve.

 

4.6.1.1

 

The sleeve will fail when a small hole is 

worn through the sleeve.  Evidence of this is that 
the foot switch will no longer turn off the flow of 
abrasive and air. 

 

4.6.1.2

 

To replace sleeve, Disconnect air and 

DEPRESSURIZE the pressure pot according to 
the instructions in operation manual.

 

Summary of Contents for 2034vx

Page 1: ... 2034vx 2034vxa Sandcarving System ...

Page 2: ......

Page 3: ...1 20 2015 3 46 PM 2034vx 2034vxa v6 0 doc Table of Contents Section 1 Safety Information Section 2 Setup Guide Section 3 Operation Section 4 Maintenance ...

Page 4: ...ir Pressure Regulator Knob Air Flow Valve Abrasive Flow Valve Air Inlet Valve Foot Switch Valve Footpedal Water Seperator Blast Nozzle Nozzle Holder Air Inlet Valve Quick Disconnect Pressure Pot Closure Lever Blast Hose Union Nut Air Pressure Regulator Gauge U U ...

Page 5: ...cabinet have seals to help keep dust out but are not explosion proof Do not blast materials that may produce combustible dusts Never use flammable solvents inside the cabinet 1 3 Dusts 1 3 1 Prolonged breathing of dusts produced by blasting media and materials removed by blasting may result in serious respiratory injury or death Health risks may vary with type of abrasive media and materials that ...

Page 6: ...to follow the procedures in this manual could result in serious injury or death from the sudden release of compressed air NEVER attempt to open the pressure pot closure mechanism using the Pressure Pot Closure Lever L This could cause a sudden UNSAFE release of compressed air The pressure pot opens automatically when the pot is depressurized Never do maintenance on any component of the pressure po...

Page 7: ...inet 2 3 Cabinet Inspection 2 3 1 Before removing the equipment from the shipping pallet inspect the cabinet for the following 1 External damage to the motor viewing glass power connections switches handles and the pressure pot 2 Check lighting fixtures inside the cabinet to make sure they are tight and have not vibrated loose in shipping NOTICE If there are any external or internal damages to the...

Page 8: ...7 Foot Petal Connection The foot petal F has a short hose and a long hose with quick disconnect fittings Connect the short hose to quick disconnect fitting on footswitch valve E Connect the long hose to the quick disconnect fitting located between water separator G and the air inlet valve C 2 8 Dust Bag Installation 2 8 1 Remove by pulling rubber plug from bottom hole The rubber plug must be used ...

Page 9: ...ing 2 11 Adding Abrasive Media The system has been shipped without the abrasive media in the pot Turn the dust collector on place unopened 50lb bag of 150 grit aluminum oxide abrasive into the cabinet Slit the center of the bag open Close the side door and empty the bag using the front armhole access After the dust has cleared remove the bag from the cabinet NOTICE The abrasive media will break do...

Page 10: ...e pot 2 13 4 Turn on the compressor and let it fully charge with air but DO NOT connect the air hose to the cabinet yet 2 13 5 Air compressors generally have an output regulator and two air pressure gauges One gauge is to indicate the pressure in the tank and the other is the output pressure the customer sets Set the output pressure regulator to 90 psi 2 14 Height Adjustment 2 14 1 The 2034vx Adju...

Page 11: ...nozzle orifices are used 3 2 Connecting Air to Cabinet 3 2 1 Before connecting the air hose from the compressor to the pot make sure the Air Inlet Valve C is in the OFF position horizontal and the air compressor has been set up according to instructions found in the Rayzist setup guide 3 2 2 Connect the compressor air hose to the Air Inlet Valve Quick Disconnect Plug N but DO NOT turn the air inle...

Page 12: ...izing the pot the pressure regulator gauge H should read about 30 psi If the gauge has a different reading make an adjustment as follows Unlock the Air Pressure Regulator Knob A by pulling upwards Twist clockwise to increase blast pressure or counter clockwise to decrease blast pressure Set regulator to desired pressure and then press down to lock the knob 3 5 Adjusting Abrasive and Air flow 3 5 1...

Page 13: ... you are done blasting or you run out of abrasive during blasting keep the dust collector turned on and then turn off the Air Inlet Valve C Then depress the foot pedal until the pot is depressurized When all the air pressure is exhausted the pot closure cap will automatically open and the abrasive that has collected in the bottom of the cabinet will flow back into the pot You can get additional ab...

Page 14: ...back into the pressure pot 4 2 1 Pinch or twist the bag tightly closed underneath the Ring Clamp then open the clamp by opening the safety lock and then the clamp lever Tie off the bag and discard 4 2 2 Slide a new bag through the Ring Clamp and fold about 3 inches of bag material over the ring Open ring clamp lever and slide bag and ring over PVC disk Close ring lever and secure safety lock 4 2 3...

Page 15: ...f glass can be sharp and cut through your skin Wear protective gloves when handling the glass 4 5 1 1 The window consists of two 12 x 24 panes of glass the outer double safety laminate replacement not required and the inner 1 8 thick single strength glass The inner single strength glass will get frosted over time and will impair visibility NOTICE 12 x 24 x 1 8 thick single strength window glass ca...

Page 16: ...cement Always Turn off unplug power from the unit Do not exceed 100 watt bulbs 4 8 4 Dust collector dust bags The dust collector bags are treated with a special non stick liner and should operate with a long life as long as daily and periodic maintenance is followed Replacement is required if any tears develop in the bag allowing dust to bypass collector and exit exhaust vent Periodically check in...

Page 17: ... Leads Green w Yellow Black White Blower Motor Electrical Connection Box 1 2 EMT From Molded Power Cord with Ground Black White White Black 110 VAC Black White Ground Lug Double Pole 10A Contact Black Green with Yellow Stripe 22mm Lever Action Switch 1 2 EMT From Molded Power Cord with Ground Copper Black Red Red Black 8 4 2 1 3 5 G Motor Leads Green w Yellow Black Red Blower Motor Electrical Conn...

Page 18: ...er Cord with Ground Black White White Black 110 VAC 1 2 LTNM conduit to actuator N C V V Blue Blue Yellow Yellow White Black AC DCConverter White Black C NC NC to actuator Black White Copper Ground Lug Enclosed Halogen Light Fixture 100w Lamp Double Pole 10 A Contact Black Green Yellow 22mm Lever Action Switch 1 2 LTNM conduit to motor 8 4 2 1 3 5 G Motor Leads Green w Yellow Black Red Blower Moto...

Page 19: ......

Page 20: ...RAYZIST COM 800 729 9478 ORDER ONLINE WWW RAYZIST COM STORE ...