RAID Storage 69
Razberi Core Server V8, V12, and V14 Factory Boot Drive and Storage RAID
Configuration
Boot Drive Factory Configuration
Core
Model
Boot Drive
RAID
Stripe
Size
Form
at
Bytes per
Sector
Bytes per
Physical
Sector
Bytes per
Cluster
V8
1
64K
4K
512
4096
4096
V12
1
64K
4K
512
4096
4096
V14
1
64K
4K
512
4096
4096
Storage Drive Factory Configuration
Core
Model
Storage
Stripe
Size
Format Bytes per
Sector
Bytes per
Physical
Sector
Bytes per
Cluster
V8
6
1M
64K
512
512
65,536
V12
6
1M
64K
512
512
65,536
V14
6
1M
64K
512
512
65,536
Razberi Core Server M4 Factory Boot Drive and Storage RAID Configuration
Boot Drive Factory Configuration
Core
Model
Boot Drive
RAID
Stripe
Size
Format Bytes per
Sector
Bytes per
Physical
Sector
Bytes per
Cluster
M4
1
64K
4K
512
4096
4096
Storage Drive Factory Configuration
Core
Model
Storage
Stripe
Size
Format Bytes per
Sector
Bytes per
Physical
Sector
Bytes per
Cluster
M4
10
1M
64K
512
4096
65,536
Summary of Contents for A8
Page 1: ...rcgs20200916 2020 2020 2020 2020 2020 2020 2020 2020 2020 ...
Page 27: ...V12 Overview 26 Figure 21 Service Information with System Touch Points ...
Page 75: ...RAID Storage 74 Select Virtual Disk Management Figure 63 PERC Adapter Server Profile View ...
Page 81: ...RAID Storage 80 Select Create Virtual Disk Figure 69 Create Virtual Disk ...
Page 82: ...RAID Storage 81 Select RAID level Figure 70 Select RAID Type ...
Page 83: ...RAID Storage 82 Select Physical Disks Figure 71 Select Physical Disks ...
Page 85: ...RAID Storage 84 Scroll up and Click Apply Changes Figure 73 Apply Changes ...
Page 86: ...RAID Storage 85 Select OK Figure 74 Confirm Completion ...
Page 89: ...RAID Storage 88 Confirm and Click Yes Figure 77 Confirm Operation ...
Page 96: ...RAID Storage 95 Verify all settings and if correct click Finish Figure 84 Complete the Wizard ...