OPERATING FRIDGE/FREEZER USING THE 12V/24V POWER CABLE CONNECTION
* The Fridge/Freezer is designed to operate on DC voltage.
* DC input 12V or 24V DC (e.g. car cigarette lighter or car battery)
General
* If the Fridge/Freezer is operating when the vehicle ignition is switched OFF, the Fridge/Freezer will switch
OFF automatically when the power source voltage falls below the set Battery proctection setting.
* The Fridge/Freezer will automatically switch back ON when the vehicle is re-started
USING THE 12V/24V POWER CABLE CONNECTION FOR THE FRIDGE/FREEZER
* Plug the 12V/24V DC power cable into the DC POWER socket at the front of the Fridge/Freezer
and connect to the vehicle cigarette lighter socket or suitable 12V or 24V DC power source.
* For optimum performance and efficiency, it is important that the Fridge/Freezer
has a reliable DC power source available. Direct connection to the battery is
recommended and reduces the risk of voltage dropping to the appliance.
* Use only the 2.0m DC power cable supplied with the Fridge/Freezer.
IMPORTANT
* When using 12V DC power supply, we recommended setting the battery protection mode to
H1 (LOW). You can find the instructions on how to set this under Operating Instructions.
* If your Fridge/Freezer is malfunctioning, it could be due to:
* The voltage protection being set too high in the battery protection mode.
* DC power cable and/or connections are not suitable to carry the required current.
* Check the power cable and all connections and adjust the Battery Monitor switch at the front of the unit.
NOTICE!
* A battery charger may only be connected to the car when the Fridge/
Freezer has been disconnected from the DC power source.
* Over-voltage may cause damage to the electronics of the Fridge/Freezer.
* Your Fridge/Freezer is equipped with reverse polarity protection. It protects your
Fridge/Freezer against reverse battery connection and short circuit.
* As a protection for your battery, the Fridge/Freezer switches OFF
automatically if the power source voltage is insufficient.
Emergency override
* If control panel malfunctions, emergency override function can be activated.
* To activate emergency override, slide emergency switch to ON.
* Temperature can not be set or adjusted when emergency override is activated.