Installing LP Gas Tank

To operate, you will need one precision-filled standard barbecue 
grill LP gas tank with external valve threads .

 

W

CAUTION: LP gas tank must be properly 

disconnected and removed prior to moving this 

griddle.

Inserting and Securing LP Gas Tank

1.  Unfold the upper LP gas tank support. 

2.  Place precision-filled LP gas tank upright onto the upper and lower LP gas tank 

support so the tank valve is facing the gas line connection.

Connecting LP Gas Tank

1.  Make sure control knobs are in the “  OFF” position (Figure 2).
2.  Before connecting, be sure there is no debris caught in the head of the LP gas tank, 

head of the regulator valve or in the head of the burner or burner ports.     

3.   Connect regulator/hose assembly to tank by turning knob clockwise until it stops.
4.  Perform leak test per “Checking for Leaks” section.

Disconnecting LP Gas Tank

1.  Make sure control knobs are in the “  OFF” 

position (Figure 2).

2.  Before disconnecting, make sure the LP gas tank 

valve is “CLOSED.”

3.  Disconnect regulator/hose assembly from LP gas 

tank by turning knob counterclockwise until it is 
loose.

 

W

CAUTION: LP gas tank must be properly 

disconnected and removed prior to 

moving this griddle.

4.  Place the protective cap cover on the LP tank and 

store the tank outdoors in a well ventilated area 
out of direct sunlight.

20 lb

9 Kg

17.9 in.

 / 45.5 cm

12.2 in. / 31 cm

Operating Instructions

Checking for Leaks

Burner Connections

1.  Make sure the regulator hose and valve 

connections are securely fastened to the 
burner and the tank.  

2.  Visually check the connection between the 

burner/venturi tube and orifice. 

3.  Make sure the burner/venturi tube fits over the 

orifice. 

 

W

WARNING: Failure to inspect this 

connection or follow these instructions 

could cause a fire or an explosion 

which can cause death, serious bodily 

injury or damage to property.   

4.  Please refer to diagram for proper installation  

(Figure 1).

5.  If the burner/venturi tube does not rest flush 

to the orifice, as shown, please contact 
1.800.694.0013 for assistance.

Tank/Gas Line Connection

1.  Make 2-3 oz. of leak detection solution by 

mixing one part liquid dish washing soap with 
three parts water.  

2.  Make sure control knobs are in the “  OFF” 

position (Figure 2).

3.  Connect LP gas tank per “Installing LP Gas 

Tank” section.

4.  Turn LP gas tank valve to “OPEN.”
5.  Spoon several drops of solution, or use a 

squirt bottle, at all “X” locations (Figures 1 
and 3).
a. If any bubbles appear, turn LP gas tank 

valve to “CLOSED,” reconnect and re-test. 

b. If you continue to see bubbles after 

several attempts, turn LP gas tank valve 
to “CLOSED” and disconnect LP gas tank, 
per “Disconnecting LP Gas Tank” section. 
Contact 1.800.694.0013 for assistance.

c. If no bubbles appear after one minute, turn 

LP gas tank valve to “CLOSED,” wipe away 
solution and proceed.

Operating Main Burners

First Use 

1.  Make sure all labels, packaging and protective 

films have been removed from the griddle. 

2.  Light griddle per “Lighting” section.
3.  Remove manufacturing oils before cooking on 

this griddle for the first time. 

4.  Season your griddle per “Seasoning Griddle” 

section.

Lighting

 

W

CAUTION: Keep outdoor gas cooking 

appliance area clear and free from 

combustible materials, gasoline and 

other flammable vapors and liquids.

 

W

CAUTION: Do NOT obstruct the flow of 

combustion and ventilation air.

 

W

CAUTION: Check and clean burner/

venturi tubes for insects and insect 

nests. A clogged tube can lead to a 

fire.

 

W

CAUTION: Do NOT use non-stick 

cooking sprays because they contain 

a lot of water and can burn onto the 

griddle, damaging the surface.

 

W

CAUTION: Do NOT use corn oil as it contains a high level of sugar, 

which can carmelize and burn onto the surface.

1.  Check for obstructions of airflow to the burners. Spiders, insects and webs can clog 

the burner/venturi tube.  A clogged burner tube can lead to a fire.

2.  All control knobs must be in the “  OFF” position (Figure 2).
3.  Connect LP gas tank per “Installing LP Gas Tank” section.

Figure 1

Figure 2

    OFF

 HIGH

 LOW

Figure 3

X

X

X

X

X

Figure 4

Lighting 
Hook

Match

Figure 5

Lighting 
Hook

Match

IMPORTANT

Before first use and after each use, always 
season your griddle per “Seasoning Griddle” 
section.

Summary of Contents for GGC2226M

Page 1: ...e property damage personal injury or death 4 This instruction manual contains important information necessary for the proper assembly and safe use of the appliance 5 Read and follow all warnings and i...

Page 2: ...types of caps or plugs may result in leakage of propane W If griddle is not in use the gas must be turned off at the supply cylinder and disconnected W Do NOT store a spare LP gas cylinder under or n...

Page 3: ...anything on the griddle while the appliance is in operation W Do NOT attempt to move griddle when in use Allow the griddle to cool before moving or storing W LP gas cylinder must be properly disconnec...

Page 4: ...3 G2225 080 8 Control Knob 3 G2225 100 9 Grease Cup G1860 060 10 Lighting Hook G2228 070 11 Regulator Hose Assembly B0308 A24 12 Left Leg Assembly G2235 070 13 Safety Latch G2235 080 14 Slide G2235 0...

Page 5: ...racks or openings 2 Spread out all parts 3 Tighten all hardware connections by hand first Then before completing each step go back and fully tighten all hardware Be careful not to over tighten That co...

Page 6: ...Outdoor Portable LP Gas Griddle Model No GGC2226M 6 5 Lock Right Leg 6 Attach Control Knobs Assembly Instructions continued...

Page 7: ...orgriddle com or call 1 800 694 0013 before returning to your retailer Griddle Storage Transporting 1 Fold Upper LP Gas Tank Support 3 Fold Griddle 4 Fold Griddle 2 Hook Regulator Hose Assembly Note T...

Page 8: ...Outdoor Portable LP Gas Griddle Model No GGC2226M 8 6 Lock Safety Latch Griddle Storage Transporting continued 1 2 3 7 Note The cart can t be removed from the griddle...

Page 9: ...roper installation Figure 1 5 If the burner venturi tube does not rest flush to the orifice as shown please contact 1 800 694 0013 for assistance Tank Gas Line Connection 1 Make 2 3 oz of leak detecti...

Page 10: ...scoloration This is normal 6 Apply cooking oil onto griddle surface inner and outer walls and evenly coat with 4 Turn LP gas tank valve to OPEN 5 Push and turn any control knob to HIGH The burner shou...

Page 11: ...reasonable proof of your date of purchase Therefore you should retain your sales slip or invoice This Limited Warranty shall be limited to the repair or replacement of parts which prove defective unde...

Page 12: ...t Out of gas Exchange refill or replace LP gas tank Overfilling prevention device may have been activated 1 Turn control knobs to OFF 2 Wait 30 seconds and light griddle 3 If flames are still too low...

Reviews: