Cyclone RazorOptimal User Manual
48 |
P a g e
Technical Services, Inc.
Proximity switch failed.
input X16. Check all the connections for this input for an open
circuit and replace cable if necessary.
If sensor indicator is off with the saw down and the cable &
wiring check out, then proximity switch has failed. Replace the
sensor.
10
ERROR #0006
‘Saw Return’ Timeout. The
upper ‘Saw Up’ proximity
switch was not activated in
the required time. Please
check Sensor X15
Saw Up flow control set too
low.
Low air pressure or leak.
Valve did not shift.
Saw motor stalled.
Proximity switch out of
alignment.
Cable or wiring problem.
Proximity switch failed.
See
Saw Flow Controls
in the
Machine Adjustment
section of
the manual for information on adjusting.
Verify adequate system air pressure. Then check for any leaks
in the air lines, check valves or cylinder on the saw cycle
cylinder.
If system air pressure is OK and valve solenoid indicator is
coming on without the saw moving down, the valve needs to be
replaced. (see Figures #7).
If saw is faulted indicating a stall, either slow the feed rate of
the saw using the flow controls or speed up the RPM of the saw
blade.
If saw is physically in down position, check that the Saw Up
prox. switch bracket and flag are tight and aligned with each
other.
If sensor indicator or PLC input X15 is off and the saw is up,
then there may be an open in the cable or wiring to PLC input
X15. Check all the connections for this input for an open circuit
and replace cable if necessary.
If sensor indicator is off with the saw up and the cable & wiring
check out, then proximity switch has failed. Replace the
sensor.
11
ERROR #0007
‘No Air Pressure detected’
(Input X13)
Air pressure supply shutoff
on the FRL is off.
Pinched or damaged air line.
Wiring problem.
Failed air pressure switch.
Turn air pressure supply shutoff on the FRL to on position.
Check air line running from the FRL to the pressure switch
mounted on the electrical cabinet. Reroute the air line if it is
pinched and replace the air line if it is damaged.
If air supply is on and air line looks good, check wiring for air
pressure switch per electrical schematics page 3.
If air supply, air line, and wiring check out, replace the air
pressure switch.
12
ERROR #0008
The ‘Saw up’ proximity
switch must be ON for the
Saw to start. (Input X15)
Low Air Pressure or air leak.
Saw was manually left
advanced.
Saw Up proximity switch is
not aligned.
Cable or wiring problem.
Proximity switch failed.
If saw is physically down, verify adequate system air pressure.
Then check for any leaks in the air lines, check valves or
cylinder on the saw cycle cylinder.
Use the valve bank to manually retract the saw by pressing the
bottom solenoid button on the saw cycle valve. See Figure #7.
If saw is physically in up position, check that the Saw Up prox.
switch bracket and flag are tight and aligned with each other.
If sensor indicator or PLC input X15 is off and the saw is
retracted (up), then there may be an open in the cable or wiring
to PLC input X15. Check all the connections for this input for
an open circuit and replace cable if necessary.
If sensor indicator is off with the saw up and the cable & wiring
check out, then proximity switch has failed. Replace the
sensor.
Summary of Contents for Cyclone RazorOptimal
Page 16: ...Cyclone RazorOptimal User Manual 16 P a g e Technical Services Inc ...
Page 22: ...Cyclone RazorOptimal User Manual 22 P a g e Technical Services Inc General Operation ...
Page 29: ...Cyclone RazorOptimal User Manual 29 P a g e Technical Services Inc Saw Stroke Distance ...
Page 45: ...Cyclone RazorOptimal User Manual 45 P a g e Technical Services Inc Pneumatic Schematics ...
Page 52: ...Cyclone RazorOptimal User Manual 52 P a g e Technical Services Inc Figure 6 Figure 7 Figure 8 ...