The following table can be used to select the correct feed nozzle:
Appendix 1
* Some products when mixed in water can be slightly viscous and the actual
rate through each nozzle may be necessary to use a larger feed nozzle.
* Sprayer calibration should be checked regularity by measuring the actual
rate. This is done by removing the feed nozzle from the spray head and
measuring the amount of spray liquid in a measuring cylinder over a period of 1
minute. When measuring the
w rate hold the sprayer at the normal spraying
angle.
NB. Actual required
w rates can be calculated using the formula in Appendix 1.
Total Spray
Volume
Swath Width
(M)
Feed
Nozzle
Flow Rate
(ml / min)
Walking Speed
(m / sec)
25
1.2
3
166
0.9
6
* Switch on the atomiser disc and then open the
w tap. Liquid should be seen
g down the hose pipe to the atomiser head.
* With the lance held preferably to the side of the operator walk at a moderate pace
(around 54 meters in one minute). This will treat a 1.2m wide strip and will cover
an area of 65 meter square each minute.
When spraying has
d close the
w tap and then switch o the atomiser.
Raise the spray head up to an angle of 45 ° (with the spray head uppermost) and
then open the tap
w valve to allow any remaining liquid in the hose pipe to
bac
For ease of transport the tank can be disconnected (use the flow valve to isolate any
liquid left in a backpack) and the sprayer collapsed (OFF the switch and disconnect the
3 pole connector).
k to the tank. Close the tap
w valve.
With the CDA sprayer, herbicides are usually applied in around 25 litres of water per
hectare.
To prepare the spray mix, select the rate of product to be applied per hectare then
add su cient water to make up to the total application volume required.
*
*
e
r
a
t
c
e
h
e
n
o
r
o
f
:
e
l
p
m
a
x
E
Glyphosate rate
-
3 litres
Add water
-
+
7 litres
Total volume
-
10 litres
Note:
When applying herbicide products ALWAYS follow the label recommendations.
MIXING AND CALIBRATION