Installation Instructions

Installation must be carried out in accordance with local authority  

 

requirements.

1.  

Installation to be in accordance with the AS/NZ3500 series of    

 

Standards plus all local and statutory requirements. For Australia,  

 

Installation shall be in accordance with the PCA [Plumbing Code of  

 

Australia] and any relevant local authority requirements. 

2. 

Flush the line thoroughly and remove all dirt and grit from the line  

 

before connecting the tap

3.  

Install the taps as shown in diagrams A-H (on page 5)

4.  

Before turning on the water, remove aerator and flush the tap

5.  

Replace aerator and check for leaks

6.  

Insert the appropriate coloured indicator into the hole at the tap base  

 

(typically blue for cold and yellow for warm water)

RBA1074-999-001 Details

The RBA1074-999-001 Angle Valve is a stop strainer that is supplied with the
Formatta Sensor Tap. This must be installed as part of the sensor tap 
installation as it prevents debris from entering the sensor and causing issues 
with diaphragm and flow control. Failure to install will void warranty.

To clean the strainer or isolate the sensor tap, simply use the special key 
provided and turn the strainer counter clock wise and remove. The angle valve 
contains a spring loaded stop that will automatically turn the water supply off 
on removal. Clean strainer or isolate tap where required. Replace strainer to 
turn the water supply back on.

+-

Summary of Contents for RBA1211-600

Page 1: ...ELBOURNE BRISBANE PERTH AUCKLAND Australia 1300 788 778 www rba com au New Zealand 0800 722 111 www rbagroup co nz 1 RBA1211 600 Formatta Sensor Tapware Sourced Supplied under QMS Date 04 08 20 Model Sensor Tapware Supercedes all previous Doc ii rba1211 600 0820 ...

Page 2: ...ffices schools shopping centres stadiums airports accessible installations The sensor detects the presence of the user s hand s in the field directly in front of the sensor in the water stream this activates the flow of water until the hands are removed from the field Technical Data Inlet BSP G1 2 Operating Pressure 200 500 kPa Flow Time On detection in field 2 seconds 60s max Maximum Temp 50ºC Fl...

Page 3: ...INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS SYDNEY MELBOURNE BRISBANE PERTH AUCKLAND Australia 1300 788 778 www rba com au New Zealand 0800 722 111 www rbagroup co nz 3 Dimensions Length 1 8M ...

Page 4: ...e 5 4 Before turning on the water remove aerator and flush the tap 5 Replace aerator and check for leaks 6 Insert the appropriate coloured indicator into the hole at the tap base typically blue for cold and yellow for warm water RBA1074 999 001 Details The RBA1074 999 001 Angle Valve is a stop strainer that is supplied with the Formatta Sensor Tap This must be installed as part of the sensor tap i...

Page 5: ...ents 2 Flush the line thoroughly and remove all dirt and grit from the line before connecting the tap 3 Install the taps according shown bellow according each model 4 Before turning on the water remove aerator and flush the tap 5 Replace aerator and check for leaks 6 Fit the appropriated water coloured indicator on the existing hole at the tap base or tap escutcheon A C E F D B 9 16 1 2 00547406 A...

Page 6: ...BA1211 999 001 M8 Locknut RBA1211 999 005 Aerator Cache HC 5Lpm w key RBA1211 999 006 Aerator key RBA1211 999 002 FORMATTA sensor RBA1211 999 003 FORMATTA valve body RBA1211 999 013 Solenoid valve RBA1211 999 004 Power supply unit RBA1074 999 001 Angled stop strainer valve key RBA1211 999 012B raided Hose RBA1211 999 001 RBA1211 999 002 RBA1211 999 003 RBA1211 999 004 RBA1211 999 005 RBA1211 999 0...

Page 7: ...rn water on Inlet valve closed or clogged Open valve or remove and clean strainer refer RBA1074 999 001 detail Aerator clogged Remove and clean aerator Braided hose kinked Replace braided hose Solenoid valve incorrectly installed Check flow direction on valve s body Reassemble if necessary Water does not flow and solenoid valve does not produce an audible CLICK No power connected Check power suppl...

Page 8: ... valve Disconnect power supply wiring under basin and connect power supply to sensor plug Ensure to also connect sensor to solenoid plug Dirt in diaphragm Turn water and power off Clean and replace diaphragm Turn water and power on Water Flows intermittent failures or incorrect function Highly reflective surface Unit not recommended for use with high polished stainless steel basins satin finish OK...

Reviews: