Page
3
of
4
•
Web Configuration Explained
Type
Use the default STATIC IP and assign a fixed IP address to the LIF-200
IP Address
Enter the required IP Address for the LIF-200.
Subnet Mask
Enter the required Subnet Mask for the LIF-200.
Gateway
The Gateway is
optional
and its requirement will depend on your network.
Primary DNS
Do Not Use
Serial Port Mode
Serial Type
Choose the serial type, RS232/RS485.
The default selection is RS232.
Baud Rate
Set up the baud rate of the serial port depending on the connected equipment.
The
default is 9600.
Reminder
Ensure the Serial Type matches the LIF unit. (232/485 switch)
Operation Mode
Connect
Mode
Only use the deault selection TCP SERVER.
Connect
Port No
Assign the TCP/IP communication port. The value
must
be the same as your
software.
The default is 3002.
Remote
Host IP
Address
This is for Client use only. Do not use.
After the hardware has been configured, ensure that the
software’s network config is programmed with the
same IP and Port No.