FUTERA II INSTALLATION AND OPERATION INSTRUCTIONS

CONTENTS

BEFORE YOUR START  .. . . . . . . . . . . . . . . . . . . . . . . . . . .    2

RATINGS & CAPACITIES. . . . . . . . . . . . . . . . . . . . . . . . . . .  3

BOILER/WATER HEATER LOCATION. . . . . . . . . . . . . . . .  3

COMBUSTION AIR & VENTILATION. . . . . . . . . . . . . . . . .  3

GENERAL VENTING GUIDELINES  . . . . . . . . . . . . . . . . .  5

OUTDOOR VENTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   18

COMMON VENT SYSTEMS . . . . . . . . . . . . . . . . . . . . . . . .  17

GENERAL PIPING REQUIREMENTS . . . . . . . . . . . . . . . .  17

HEATING SYSTEM PIPING. . . . . . . . . . . . . . . . . . . . . . . . .  19

DOMESTIC WATER SUPPLY PIPING  . . . . . . .  . . . . . . . .  23

GAS SUPPLY PIPING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  27

ELECTRICAL WIRING . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  28

GENERAL OPERATION. . . . . . . . . . . . . . . . . . . . . . . . . . . .  28

OPERATING INSTRUCTIONS. . . . . . . . . . . . . . . . . . . . . .   28 

CHECKING & ADJUSTMENTS. . . . . . . . . . . . . . . . . . . . . .  30 

CONTROL DESCRIPTION. . . . . . . . . . . . . . . . . . . . . . . . .   32

DIAGNOSTIC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   33 

MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   34

TROUBLE-SHOOTING. . . . . . . . . . . . . . . . . . . . . . . . . . . .   37

REPAIR PARTS. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  37

START UP SHEET. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .    41

WARRANTY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .   44

BEFORE YOU  START

 

This manual covers the application, installation, operation 

and maintenance of a Futera II Series finned copper 

heating boiler/water heater/pool heater.

 

To obtain the safe, dependable, efficient operation and long 

life for which this heating boiler/water heater was designed, 

these instructions must be read, understood and followed.

The Futera II Series finned copper heating boiler/

water heaters have been design certified by CSA for 

use with natural and propane gas under the latest 

revision of ANSI-Z21.10.3/CSA 4.3, Gas Water 

Heaters, ANSI-Z21.13/CSA 4.9, Gas-Fired Low 

Pressure Steam and Hot Water Boilers ANSI-Z21.56/

CSA 4.7 Gas Fired Pool Heaters (Canada Only). 

Each unit has been constructed and hydrostatically 

tested for a maximum working pressure of 

160 psi

,  

1103 kPa in accordance with Section IV of the A.S.M.E. 

Boiler and Pressure Vessel Code.

All aspects of the boiler/water heater installation must 

conform to the requirements of the authority having juris-

diction, or, in the absence of such requirements, to the 

National Fuel Gas Code, ANSI Z223.1/NFPA 54-latest 

revision. Where required by the authority having jurisdiction, 

the installation must conform to the Standard for Controls 

and Safety Devices for Automatically Fired Boilers, ANSI/

ASME CSD-1.

In Canada, the installation must be in accordance with the 

requirements of CSA B149.1 or .2, Installation Code for 

Gas Burning Appliances and Equipment.

The owner should maintain a record of all service work 

performed with the date and a description of the work done.   

Include the name of the service organization for future 

reference.

 

Direct all questions to your RBI distributor or contact the 

RBI Customer Service Department at: 

 

U.S. —

 

260 North Elm Street

 

Westfield, MA 01085 

 

Canada —

 

7555 Tranmere Drive

 

Mississauga ONT L5S 1L4 

Always include the model and serial numbers from the 

rating plate of the boiler/water heater in question.

Summary of Contents for FUTERA II 1000

Page 1: ...uction dust and particulate particularly drywall dust will cause contamination of the burner resulting in possible severe personal injury death or substantial property damage The boiler can only be op...

Page 2: ...as Fired Low Pressure Steam and Hot Water Boilers ANSI Z21 56 CSA 4 7 Gas Fired Pool Heaters Canada Only Each unit has been constructed and hydrostatically tested for a maximum working pressure of 160...

Page 3: ...er heater in a location that would restrict the introduction of combustion air into the unit or subject it to a negative pressure see GENERAL VENTING GUIDELINES 6 NEVER place this boiler water heater...

Page 4: ...st be given to the blockage effects of louvers grills and screens Screens must have a minimum mesh size of 1 4 in 6 4 mm If the free area through a louver or grill is not known ducts should be sized p...

Page 5: ...the horizontal combustion air pipe on installations that used the Direct Vent option is 60 ft 18 3 m The maximum equivalent length for the horizontal combustion air pipe on installations that use the...

Page 6: ...61 cm from the center line of the terminal E Clearance to unventilated soffit F Clearance to outside corner G Clearance to inside corner H Clearance to each side of center line extended above meter re...

Page 7: ...3 kW and 100 000 Btuh 30 kW 36 in 91 cm for appliances 100 000 Btuh 30 kW 4 ft 1 2 m below or to side of opening 1 ft 300 mm above opening C Clearance to permanently closed window D Vertical clearance...

Page 8: ...or balcony is fully open on a minimum of two sides beneath the floor NOTES 1 In accordance with the current CSA B149 1 Natural Gas and Propane Installation Code 2 In accordance with the current ANSI Z...

Page 9: ...meters gas meters regulators and relief equipment and not less than 7 ft 2 1 m from any adjacent public walkway The bottom of the vent terminal s shall be located at least 5 ft 1 5 m above the air in...

Page 10: ...10 FUTERA II INSTALLATION AND OPERATION INSTRUCTIONS Figure 1 Air Intake Vertical or Thru Wall Figure 2 Venting Thru Wall Vertical...

Page 11: ...gle or multiple units exhaust and combustion air terminals must be installed on the same plane outside wall in order to prevent pressure differences due to prevailing winds In cold climates double wal...

Page 12: ...AND OPERATION INSTRUCTIONS Figure 5 Vertical Air Intake and Venting for Direct Vent System Figure 6 Combination Direct Vent Systems 10 FT 3 1 m 4 FT 1 2 m 5 FT 1 5 m 1 5 FT 0 5 m 5 1 2 FT 1 7 m 1 5 FT...

Page 13: ...venter for the boiler water heater see Table 4 Follow the power venter manufacturer s installation instructions Table 4 Power Venter Sizes VERTICAL CHIMNEY VENT NEGATIVE PRESSURE CATEGORY I The Futer...

Page 14: ...ingle wall vent connection with at least 3 corrosion resistant sheet metal screws Always provide a minimum clearance of 6 in 152 mm between single wall vent pipe and any combustible materials Type B1...

Page 15: ...15 FUTERA II INSTALLATION AND OPERATION INSTRUCTIONS Figure 8 Vertical Venting with a Metal Chimney System...

Page 16: ...r window or gravity air inlet into any building and at least 3 ft 1 m from any overhang unless local codes dictate differently Avoid locations where wind deflection off of adjacent walls buildings or...

Page 17: ...marche Suivre les instructions d allumage R gler le thermostat de fa on que l appareil fonctionne de fa on continue e Test for spillage at the draft hood relief opening after 5 minutes of main burner...

Page 18: ...water mix that prevents foaming Air entrapped within foam significantly decreases heat transfer and can result in damage to the heat exchanger Products such as DOWFROST DOWTHERM UCARTHERM or an equiva...

Page 19: ...4 C The adjustable pump delay turns the pump on each time the burner fires and runs the pump for 6 to 600 seconds after the call for heat is satisfied CAUTION A temperature rise outside of the range...

Page 20: ...econdary systems In order to prevent boiler s short cycling the system flow must be equal to or higher than the boiler s local flow Low Return Water Temperatures To prevent the problems associated wit...

Reviews: