8
MORE PAD INDOOR
•
Read the labels on the packaging to
check that the product is correct for the
installation being carried out;
•
Installation must be carried out by qualified
personnel who have been trained in
advance, including with the aid of this
manual;
•
Avoid direct contact of the technopolymer
with aluminium and/or aluminium alloy
components to prevent possible interaction
with the molecular vibration of the
technopolymer;
•
The PAD INDOOR can be cut to size as
there is no minimum length required;
•
Any scraps can be reused by electrically
wiring them together to give electrical
continuity between the mat portions;
•
It can be cut or drilled, in case of
interference with obstacles (e.g. electrical
boxes), as long as the lateral electrical
conductors are not interrupted;
•
It can be nailed and/or stapled for fixing
to the substrate at any point, taking care
to avoid affecting the lateral electrical
conductors;
2.6 GENERAL INFORMATION FOR INSTALLATION
•
It can also be curved and bent at right
angles (between slats) to fit the profile to be
heated;
•
Do not allow metal parts that pass through
or touch the mat (e.g. paper clips, drywall
screws, etc.) to come into contact with
metal masses. If this were to happen, the
area in which contact takes place could be
subject to a significant reduction in surface
temperature due to the alteration of the
transit of electrical energy;
•
Avoid contact with solvents as well as with
glues and two-component mortars that
could compromise the long-term stability of
the technopolymer;
•
The surface of the mat can be covered
with any type of building finish (including
tiles, natural stone, parquet, cement mortar
plaster, laminate and carpet); the transfer
of thermal energy must take place by
contact between the layers that interpose
themselves with the environment to be
heated;
2.7 GENERAL INFORMATION ON ELECTRICAL INSTALLATION
•
The electrical wiring must be sized and
executed in accordance with Italian
Presidential Decree 37/08 and subsequent
amendments and integrations;
•
The installation must be carried out by a
qualified installer, following the rules of art
set out in the current technical regulations
for the installation of electrical systems as
well as in this installation manual, using
certified products that allow the declaration
of conformity to be issued;
•
If the rooms served by a single electric
meter exceed the size or installed power
limits laid down in Italian Ministerial Decree
37/08, the electrical dimensioning of
the system and the related project must
be drawn up and signed by a qualified
professional registered with a professional
association;
•
The PAD INDOOR heating system,
consisting of the radiant mat and its
accessories, such as self-amalgamating
tape, crocodile crimp terminals and power
supply drivers 320 and 600, enables the
creation of an electrical system in insulation
class III SELV to allow installation in special
environments such as wet rooms and
shower compartments