IMPORTANT
READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
RC’s PL floods must be wired in accordance with
the National Electrical Code and applicable local
codes. Proper grounding is required for safety.
The PL floods are for outdoor use and should not be
used in areas of limited ventilation or high ambient
temperatures. All work should be done by a qualified
electrician.
Fixture should be located at least 18" below any
overhang or other structural detail. Fixture should
not be recessed.
WARNING: Make sure power is OFF before installing or maintaining fixture.
CAUTION: To avoid a possible shock hazard, do not connect wires until fixture is twisted into mounting hole.
LOCATION
The PL floods can be mounted to any 1/2’’ NPS
mounting hole.
1. Route fixture leads through the mounting hole.
2. Twist PL flood foot into mounting hole.
3. Tighten locknut.
MOUNTING
(over)
Thank you for buying RC Lighting fixtures. Our aim is to design the best quality products so you can get the job
done right. We’d like to hear your comments. Call us at 888-722-1000, attention Marketing Department.
PLF13 AND PLF26 FLUORESCENT FLOODS
Installation Instructions
Listed
For Wet
Locations
WIRING
Use supply wire rated for 90°C.
1. Connect the fixture lead to the black supply lead.
2. Connect the common fixture lead to white supply lead.
3. Connect supply ground wire to fixture ground screw.
PLF
LIGHT
FIXTURE
BLACK BLACK
WHITE (–) COMMON
GROUND
SUPPL
Y