background image

SYMPTOMS

POSSIBLE CAUSE

REMEDY

 

Door will not operate

 Main power not turned on

 Turn on

 Door is obstructed

 Remove obstruction

 Fuse blown 

 Replace fuse

 Door will not operate

 Door reversing sensitivity not

 Re-adjust reversing sensitivity

adjusted properly

(Ref installation instruction step 7)

 Door moves downwards

Door reversing sensitivity not

  Re-adjust reversing sensitivity

and reverses itself upwards

adjusted properly

(Ref installation instruction step 7)

  Door operates from drive

Indicator on transmitter

Battery flat of battery leads broken

unit but not from hand transmitter

not lighting

 Transmitter has not been learnt

Refer to installation

instructions - step 8

Drive unit aerial wire not extended

Extend aerial wire

 Battery flat

Replace battery

 Door does not close fully

Limit micro switch

Re-adjust limit switch

incorrectly adjusted

(refer to intallation

instructions step 6)

 Door does not open fully

Limit micro switch

Re-adjust limit switch

incorrectly adjusted

(refer to intallation

instructions step 6)

lights not functioning

Bulb blown

Replace bulb

 Bulb keeps blowing

 Incorrect bulb

Replace with 24V 5 Watts

Festoon bulb

FAULTS AND REMEDIES

Specifications

INPUT VOLTAGE:

110/220V AC 50Hz

Single Phase.

Current Required

1 Amp

TRANSFORMER SPEC: 

Primary Voltage

110/220 VAC

Secondary Voltage

24V AC/100VA

MOTOR SPEC:

Motor type

Permanent Magnet DC Motor

Torque

150kg cm at 4 Amps

OPENER LIFTING CAPACITY:

30kg

CONTROL BOARD SPEC:

Relay Contact Rating

12 Amp/30V DC

Relay Coil Voltage

24V DC

Control Board Voltage

24V DC/5V DC

Light Globe Voltage

24V DC 5 Watts

Receiver Specification

Receiver Type

FSK AM

RF Frequency

433.92 MHz

Code Storage Capacity

6 different codes

Control Distance

>50m

TRANSMITTER SPEC:

Carrier Frequency

433.92 MHz

Current Consumption

50mA (approx.)

Battery Voltage

12 Volts

Coding Format

Rolling Code (7.38 x 1019 Code Combinations)

Summary of Contents for Orca GarageAce

Page 1: ...r is completely closed NO ONE SHOULD CROSS A MOVING DOOR Do not operate the door opener manually with people or any object including motor vehicles within the doorway The garage door must be well balanced Sticking or binding doors can falsely trigger the obstruction detection All maintenance must be carried out by a suitably qualified person Test the door opener monthly The garage door MUST revers...

Page 2: ...ctly adjusted refer to intallation instructions step 6 Door does not open fully Limit micro switch Re adjust limit switch incorrectly adjusted refer to intallation instructions step 6 lights not functioning Bulb blown Replace bulb Bulb keeps blowing Incorrect bulb Replace with 24V 5 Watts Festoon bulb FAULTS AND REMEDIES Specifications INPUT VOLTAGE 110 220V AC 50Hz Single Phase Current Required 1...

Page 3: ...mory device 9 RF RECEIVER Board 433 92MHz AM FSK mode receiver 10 ANTENNA do not cut antenna wire or coil up 11 UPWARD FORCE Adjustment Model A only is for adjusting the open obstruction force Turning the shaft in a clockwise direction increases the force that is required to restrict the door before it stops when opening Turning anti clockwise will decrease the force that is required to stop the d...

Page 4: ...ing weight bars Figure 2 shows the weight bars attached If the door feels heavy it may require extra tension to be added to the door springs Refer to the door manufacturer s installation instructions on how to tension the door Right Hand Left Hand Green Red Green Red Red Yellow Red Yellow Figure 3 1 Before beginning the installation check operation of the door The door must be well balanced and be...

Page 5: ...unting bracket to the wall Make sure the door will still be level in some cases the bracket Red Cord may have to be repositioned j Straighten the drive unit and position over the wall bracket Refit the original U bolt through the slots in the drive unit and into the bracket k If the original U bolt does not fit through the slots discard it and use the supplied U bolt instead You may have to drill ...

Page 6: ...lockwise until the door stops momentarily then reverses c Turn the DOWN FORCE knob 10 degrees clockwise Press the 0 S C button again to close the door If the door reverses by itself readjust the DOWN FORCE knob a further 5 degrees clockwise Keep adjusting in this manner until the door can complete the full closing cycle Obstruction detection force level for OPEN a Fully close the door by pressing ...

Page 7: ...umber of combinations to 7 38 x 1019 There are no Dip switches on the opener which can be visually seen and copied Open and Close Drive Button Another feature developed to aid in the installation of the opener are the 0 S C Buttons These buttons are used to help set the open and close limit positions The quicker setting time and a more precise limit position can be achieved using this system Auto ...

Page 8: ... home garage vehicle caravan boat A small sized extinguisher that packs a powerful punch Designed for class A B and E fires the SafetyAce is just what you need Cat OSA FE Don t forget these other great ORCA products SafetyAce Smoke Alarm Range ...

Reviews: