19
18
18
17
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
CONTROL DEFINITIONS
Control Definitions
(DIY installation points are in bold. Other points are of interest to qualified
electrical installers only)
1 .
O/S/C Button
, is used during installation to open, stop and close the
opener.
2.
EXT Push Button
, is for connecting the wall switch, with the same
function as the 0/S/C Button.
3.
EXT ALARM
, is for connection the extra alarm siren, accomplish the anti-
theft function via the A-SW input at the CONTROL TERMINAL.
4.
+24V, PB and GND
, is for connecting the 2-wire or 3-wire Photo Electric
Beam.
5.
A-SW and GND
, is for connecting the anti-theft sensor, broken at the
full close position will activate the EXT. ALARM output.
6.
PUSH and GND
, is for connecting the PUSH BUTTON, with the same
function as the 0/S/C button.
7.
LEARN LED
, to indicate the learn/working status of the transmitter(s).
8,
LEARN BUTTON
, is used for storing or erasing your selected security
code from your transmitter(s) into the openers memory device.
9.
RF RECEIVER
Board, 433.92MHz AM FSK mode receiver,
10.
ANTENNA
, do not cut antenna wire or coil up.
11.
UPWARD FORCE Adjustment
. (Model A only), is for adjusting the
open obstruction force. Turning the shaft in a clockwise direction increases
the force that is required to restrict the door before it stops when opening.
Turning anti-clockwise will decrease the force that is required to stop the door.
12.
DOWNWARD FORCE Adjustment
, is for adjusting the close safely
obstruction force. Turning the shaft in a clockwise direction increases the force
that is required to restrict the door before it reverses when closing. Turning
anti-clockwise will decrease the force that is required to reverse the door.
13.
AC POWER
, is for connecting the main power supply. AC 24V. 50-
60Hz.
14.
LAMP
, the courtesy light, with the rating 8W/24V.
15.
TO DC MOTOR
, is for connecting the opener, the DC motor output.
16.
OPENICLOSE
limits connector, Pin 4-5, the open limit input and pin 5-
6, the close limit input. Normal contact and activate while the switch opens.
17.
BATTERY BACKUP CONNECTION
, for use with 24V battery back
up.
18.
FUSE
. 5 x 20mm normal Blow Glass Fuse, 7A 240V.
19.
BEEPER
, on Board Beeper when in operation.