4. Insert Power Cord into socket located in the back of the
RCBS Ultrasonic Cleaning Unit. See
Photo 6
5. Plug opposite end of Power Cord into a grounded 120VAC
wall socket.
6. Turn the On/Off switch to the On position, see
Photo 7
.
7. Set temperature by depressing Temp Button until desired
temperature is displayed.
8. When fluid reaches desired temperature, slowly place
loaded basket into Ultrasonic Cleaning Unit.
9. Place lid securely onto Ultrasonic Cleaning Unit.
10. Set time by depressing Time Button until desired time is
displayed.
11. If Degassing is desired, depress Function Button until the
symbol is displayed.
12. If Degassing is not desired, the
symbol will be
displayed, specifying normal cleaning operation.
13. Ensure the Green ready light is illuminated.
14. Depress the On/Off button to initiate cleaning. You will
hear a buzzing sound indicating the Ultrasonic Cleaner
has begun the cleaning cycle.
15. If the degassing function is being used, the unit will cycle on and off for 2 minutes until the degassing
operation is completed, at which time the degassing symbol will no longer be illuminated in the display and
normal cleaning operation will begin.
16. Once the Ultrasonic Cleaner has been in operation for the desired time the unit will automatically shut off.
17. When cleaning has been completed, turn off the Power Switch, located in the back of the unit, see
Photo 6
.
18. Unplug Power Cord from wall socket.
19. Remove the lid and remove basket from Ultrasonic Cleaner.
20. Place basket inside another container and follow directions on the cleaning solution being used regarding
rinse or no rinse. If rinising is indicated, agitate items in rinse water and continue to rinse until all cleaning
solution has been rinsed from items. Be sure to discard rinse water and cleaning solution according to
cleaning solution manufacturers recommendations and local disposal regulations.
21. Place cleaned items onto a clean, dry surface. Spread items out and allow to dry. Drying time can be
reduced by using a hair dryer, or placing in direct sunlight.
22. If more cleaning is necessary repeat steps 5 through 16 mentioned above. If cleaning solution is dark and
murky it will need to be replaced. If cleaning is completed proceed to
step 23
.
23. Attach drain hose to drain or place a 6.0L/1.6 gal. reservoir below drain. Rotate Drain Valve clockwise 90
degrees to begin draining fluid from tank, see
Photo 8
.
24. When tank has been completely drained, rinse tank with clean water, rotate Drain Valve counter-clockwise
90 degrees to close drain, as shown in
Photo 2
.
25. Wipe tank and other areas of cleaner with a clean dry cloth to remove any excess moisture accumulated
during use.
26. Store unit in dry, cool ventilated area.
INDIRECT CLEANING METHOD
NOTE: Indirect Cleaning is an enhanced cleaning method, which can be used for parts that are difficult to clean
using the standard cleaning method.
1. Place items in Stainless Steel Tub - small.
2. Add cleaning solution to completely cover parts in Stainless Steel Tub - small.
3. Place Stainless Steel Tub - small into Ultrasonic Cleaner-2.
4. Add water to tank to a level between Min and Max, do not overfill to allow water to run into container.
5. Run Ultrasonic Cleaner-2 as specified above in OPERATING INSTRUCTIONS
On/Off Switch in ON Position
Photo 7
Drain Valve in
Open Position
Photo 8
8
Summary of Contents for ULTRASONIC CASE CLEANER-2
Page 1: ...ULTRASONIC CASE CLEANER 2 PRODUCT INSTRUCTIONS 87061...
Page 2: ......
Page 3: ...CONTENTS English Fran ais Espa ol Deutsch Italiano 1 10 11 20 21 30 31 40 41 50...
Page 8: ...5 3 1 2 4 6 5 7 10 9 8 11 12 13 15 16 17 14 DISPLAY and KEYPAD...
Page 18: ...15 3 1 2 4 6 5 7 10 9 8 11 12 13 15 16 17 14 CRAN ET CLAVIER...
Page 28: ...25 3 1 2 4 6 5 7 10 9 8 11 12 13 15 16 17 14 PANTALLA y TECLADO...
Page 38: ...35 3 1 2 4 6 5 7 10 9 8 11 12 13 15 16 17 14 ANZEIGE und TASTENFELD...
Page 48: ...45 3 1 2 4 6 5 7 10 9 8 11 12 13 15 16 17 14 DISPLAY e TASTIERINO...