background image

7

ENGLISH

IMPORTANT NOTES

Before  connecting  and  using  this  paging  microphone,  please  read  this 
instruction  manual  carefully  and  keep  it  on  hand  for  future  reference. 
The  manual  is  to  be  considered  an  integral  part  of  this  product  and  must 
accompany it when changing ownership as a reference for correct installation 
and use as well as for the safety precautions. 

RCF

 S.p.A. will not assume any 

responsibility for the incorrect installation and / or use of this product.

SAFETY PRECAUTIONS

1.

  All  the  precautions,  in  particular  the  safety  ones,  must  be  read  with 

special attention, as they provide important information.

2.  

Make sure all connections have been made correctly before switching all 
devices on.

 

Do not connect / disconnect the paging microphone when the system is 
operating. 

3. 

  Protect  the  paging  microphone  cable  from  damage  and  assure  it  is 

positioned where it cannot be stepped on or crushed by objects.

4.

   Do not put the paging microphone into water (or another liquid), do not 

throw it.

5.

   Never attempt to carry out any operations, modifications or repairs.

 

If the paging microphone does not work properly, contact your authorized 
service centre.

6.

   Assure the paging microphone cable is balanced, as this is required by 

“phantom” power supply.

7.

   Should the paging microphone emit any strange odour or even smoke, 

turn the sound system off immediately.

8.

   RCF S.p.A. strongly recommends the sound system installation is only 

made by professional qualified installers (or specialised firms), who can 
certify it according to the regulations in force.

 

The  entire  audio  system  must  comply  with  the  current  standards  and 
regulations regarding electrical systems.

Summary of Contents for BM3001

Page 1: ...the rules of sound BM3001 User manual Manuale d uso Manuel de l utilisateur BASE MICROFONICA DA TAVOLO DESKTOP PAGING MICROPHONE MICROPHONE D ANNONCE POUR PUPITRE...

Page 2: ...ando il sistema acceso 3 Accertarsi che il cavo della base microfonica non possa essere calpestato o schiacciato da oggetti al fine di salvaguardarne l integrit 4 Non immergere la base microfonica nel...

Page 3: ...l esposizione Per evitare un esposizione potenzialmente pericolosa ad elevati livelli di pressione acustica necessario che chiunque sia sottoposto a tali livelli utilizzi delle adeguate protezioni qua...

Page 4: ...c c Gli ingressi 2 e 3 degli amplificatori RCF ES 3160 AM 2160 e AM 2320 tutti con funzione Smart disattivabile hanno ciascuno un connettore RJ 45 per la rapida connessione di una base microfonica BM...

Page 5: ...tivo durante un annuncio utile per ottenere la priorit 3 Selettore Local Remote LOCAL La base microfonica funziona indipendentemente dalla presenza o meno del comando d abilitazione input enable da ut...

Page 6: ...rofono Phantom 18 48 V c c Assorbimento 2 8 mA Dimensioni 100 x 159 x 48 mm senza braccio flessibile Peso 0 7 kg Accessori a corredo Cavo CAT5 FTP 5 m BM3001 BM3001 Marrone Biancomarrone Verde Biancob...

Page 7: ...ct the paging microphone when the system is operating 3 Protect the paging microphone cable from damage and assure it is positioned where it cannot be stepped on or crushed by objects 4 Do not put the...

Page 8: ...and depends on the duration of exposure To prevent potentially dangerous exposure to high levels of acoustic pressure anyone who is exposed to these levels should use adequate protection devices When...

Page 9: ...nputs 2 and 3 of amplifiers ES 3160 AM 2160 and AM 2320 all with switchable Smart function have an RJ 45 socket each to connect a BM 3001 paging microphone quickly through CAT 5 cable Amplifiers AM 20...

Page 10: ...l to get the priority 2 3 3 Local Remote Switch LOCAL The paging microphone can always be switched on even if the enable command is not present Choose this mode when connecting the BM 3001 paging micr...

Page 11: ...upply Phantom 18 48 V dc Consumption 2 8 mA Dimensions 100 x 159 x 48 mm without gooseneck Weight 0 7 kg Included accessories 5 m CAT5 FTP cable BM3001 BM3001 Brown Brown White Green Blue White Blue G...

Page 12: ...12 fran ais...

Page 13: ...pareils Ne connectez d connectez pas le microphone d annonce lorsque le syst me fonctionne 3 Prot gez le c ble du microphone d annonce contre tout dommage et assurez vous qu il est plac de sorte qu il...

Page 14: ...et d pend de la dur e d exposition Pour se pr munir contre les niveaux de pression acoustique lev s toute personne expos e doit s quiper d un dispositif de protection adapt Vous devez porter des bouc...

Page 15: ...des entr es 2 et 3 des amplificateurs ES3160 AM2160 et AM2320 tous quip s d une fonction Smart commutable poss de un port RJ 45 permettant de connecter rapidement un microphone d annonce BM3001 par le...

Page 16: ...S lecteur Local Remote LOCAL Le microphone d annonce peut toujours tre allum m me lorsque la commande Enable autorisation est absente Choisissez ce mode si vous reliez le micro d annonce BM3001 un am...

Page 17: ...ation fant me de 18 48 V DC Consommation 2 8 mA Dimensions 100 x 159 x 48 mm sans le flexible Poids 0 7 kg Accessoires inclus C ble FTP CAT 5 de 5 m tres BM3001 BM3001 Marron Marron blanc Vert Bleu bl...

Page 18: ......

Page 19: ......

Page 20: ...0307164 C Salvo eventuali errori ed omissioni RCF S p A si riserva il diritto di apportare modifiche senza preavviso Except possible errors and omissions RCF S p A reserves the right to make odificati...

Reviews: