43
ENGLISH
SYS CONFIG > GPO SUBMENU
Configuration of the 8 logic outputs (GPO) of the main unit (and of all amplifiers).
Choose either
MAIN UNIT GPO
to access the main unit GPO list or
BOARD GPO
to
access the selected board GPO list.
Then, select a logic output (GPO) to enter its respective submenu:
CONFIG:
SET PRIO
Priority setting (lower number: higher priority).
MONITORING
It enables (
On
) / disables (
Off
) GPI line monitoring.
STATUS
GPI default status. Choose either
Normal Open
or
Normal Close
(normally open/closed).
ENABLE
It enables (
On
) / disables (
Off
) the selected GPO.
ASSIGN:
logic output mode and function settings (see the following table).
FUNCTION
DESCRIPTION
NO FUNCTION
No function assigned.
PERIODIC
Its activation is repeated once or more times (TIME) or
in defined days (SCHEDULE).
As example, see the AUDIO SET > ROUTN PROG
submenu.
ROUTINE MESSAGE
Its activation is due to routine message playback
(a message chosen among the ones matched to
events).
FAULT IN PROGRESS
Its activation is due to a fault detection.
EVAC IN PROGRESS
Its activation is due to evacuation in progress.
ALERT IN PROGRESS
Its activation is due to alert in progress.
ALL-CLEAR IN PROGRESS
Its activation is due to the ‘all clear’ message playback.
TEST IN PROGRESS
Its activation is due to the ‘test’ message playing.
BUSY ZONE
Its activation is due to a busy zone.
DELAY:
it allows to delay GPO activation and release.
It opens a further submenu:
- ACTIVATION TIME:
delay time setting of GPO activation.
- RELEASE TIME:
delay time setting of GPO release.
- OVERRIDE:
it is possible to cancel the GPO activation if either a main unit GPI (MAIN UNIT
GPI) or a slave board GPI (BOARDS GPI) is here selected and then activated.
SYS CONFIG >
GPO SUBMENU