Specifications

MECHANICAL 

(Including 1/4” [6.4mm] mounting bracket)

:

8310 Lock Dimensions:

1 5/8”D x 2 7/8”W x 10 1/2”L (41mm x 73mm x 268mm)

8320 Lock Dimensions: 

1 5/8”D x 2 7/8”W x 21”L (41mm x 73mm x 533mm)

8330 Lock Dimensions: 

1 5/8”D x 2 7/8”W x 34 1/2”L (41mm x 73mm x 876mm)

8340 Lock Dimensions: 

1 5/8”D x 2 7/8”W x 46 1/2”L (41mm x 73mm x 1181mm)

NOTE: Both 8330 and 8340 housings may be cut to length on site

Standard Armature plate dimensions: 

5/8”D x 2 3/8”W x 7 7/16”L (16mm x 60mm x 189mm)

DSS Armature plate is 10”L (254mm) 

ELECTRICAL:
Voltage:

12VDC or 24VDC 

(Selected by choosing appropriate wiring terminals)

Current:

0.28A @ 12VDC
0.28A @ 24VDC

NOTE: 8320 lock contains 2 control boards 

that will each draw 0.28A 

SCS Output Relay:

SPDT relay. Contacts rated at 1.25A@24VDC

DSS Reed Switch:

Magnetically actuated SPDT switch.

Contacts rated for 0.20A @12VDC and 0.12A @ 24VDC

ENVIRONMENTAL:

Not for use in outdoor environments.

Circuit board operating temperature: -14 to 140˚F (-10 to 60˚C)

NOTE: Specifications may change without notice.

8300 Series Troubleshooting Guide

Problem

Solution

Remove anti-tamper screw and cavity screw. Insert supplied Allen wrench into

mounting bolt holes in the bottom of the lock housing and turn. (See Fig.3)

-

Check power supply. DC power should be slightly over the voltage

specifications outlined on the packaging. eg: for 12VDC operation

supply should be set at 12VDC-13VDC.

-

Check connections at power supply, connected releasing devices, lock

terminals and lock circuit board to magnet core.

-

Check delayed relock wiring and time setting

-

Check that the momentary switch does not include a shunted light option

Check to see that armature plate is correctly aligned with the

electromagnetic lock. If there is improper alignment, make a 1/4” turn of the

armature plate mounting bolt and check for alignment. 

CAUTION:

The

armature plate must remain affixed securely to the door or serious bodily

injury or property damage may occur.  Bolt should be tight enough to hold

the armature plate to the door while still allowing for alignment with the

electromagnetic lock. 

This generally indicates that the lock is either operating on AC voltage or there

is some AC voltage present in the DC supply. A properly filtered and regulated

DC power supply is required to achieve optimal operation from the lock.

Ensure that switching devices are interrupting the DC power and not the

AC power supply voltage. 

Ensure rubber washer on armature plate mounting bolt has not been 

removed or damaged

Check that switching device interrupts the positive wire and not the 

negative wire (See Fig. 2)

Remove any Diodes or other suppression devices that may be installed

Cannot remove the lock mounting bracket from top of

magnet for installation.

Lock is installed but has no holding force at all.

Lock has enough holding force to lightly hold a

screwdriver or set of pliers but door will not lock.

Lock is operating and locking but the armature plate is
“humming” against the surface of the lock.

Lock is not releasing immediately upon removal of power

8310, 8320, 8330 & 8340 Electromagnetic Lock

Installation Instructions 

(Continued)

4

NOTE:

All RCI electromagnetic locks must be powered with filtered and regulated DC power supplies such as the RCI 10 Series UL

Listed power supply. RCI offers a full line of power supplies and switching devices that are suitable for use with the 8300 Series locks.

Voltage

8310

8320

8330

8340

12VDC

0.28A

0.28A x 2= 0.56A

0.28A

0.28A

24VDC

0.28A

0.28A x 2= 0.56A

0.28A

0.28A

Power Supply

Summary of Contents for 8310

Page 1: ... to the Product Accessories Guide section of the Installation Instructions for further information 10 Installation of this product should be done by an experienced installer with knowledge of this product NOTE It is highly recommended that thread locking compound be applied to all screws during installation to reduce chance of screws loosening over extended time IS8310 40 PCN070022 B P11 07DA 1 Mo...

Page 2: ...Release All switching devices must be wired in between the DC power source and the positive terminal of the lock in Fig 2 Switching the negative power supply line will not allow the lock to release immediately RCI electromagnetic locks contain MOV s for surge suppression and do not require any additional suppression to be added during installation The installation of diodes across the lock input t...

Page 3: ...ed for 24VDC That signals a monitored system or guard station that the holding force of the lock may have been compromised DSS Door Status Sensor The DSS option monitors the position of the door upon which the lock is installed A SPDT reed switch mounted within the lock cavity eliminates the need for extra sensors to be installed on the door for notification of security or access control systems T...

Page 4: ...e plate is correctly aligned with the electromagnetic lock If there is improper alignment make a 1 4 turn of the armature plate mounting bolt and check for alignment CAUTION The armature plate must remain affixed securely to the door or serious bodily injury or property damage may occur Bolt should be tight enough to hold the armature plate to the door while still allowing for alignment with the e...

Page 5: ...nsufficient space on the frame header to mount the lock The lock mounts to the underside of the L bracket and the L bracket then gets mounted to the doorframe Available in several different sizes and finishes Available for all 8310 and 8320 locks Allows an armature plate to be mounted to a glass or Herculite door that does not have a frame The Glass Door Bracket is a U shaped piece of 1 16 thick m...

Page 6: ...bar can be used to lower the lock from the frame Available in several different heights For use with doors that do not permit the armature plate to be mounted low enough to meet the magnet surface Eg Some aluminum framed commercial glass doors The armature holder can be mounted to whatever frame is available and the armature plate in turn mounted to the holder Available in both flat shown and pock...

Page 7: ...A 2A 3A Wire Run ft 100 24 20 18 18 16 16 14 12 150 22 18 16 16 14 14 12 10 200 20 18 16 14 14 12 12 10 250 18 16 14 14 12 12 12 10 300 18 16 14 12 12 12 10 400 18 14 12 12 10 10 500 16 14 12 10 10 750 14 12 10 10 1000 14 10 10 1500 12 10 Total One Way Length of 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A Wire Run ft 100 20 18 16 14 14 12 12 10 150 18 16 14 12 12 12 10 200 16 14 12 12 10 10 250 16 14 12...

Page 8: ...8310 8320 8330 8340 Electromagnetic Lock Installation Instructions Continued Maintenance Schedule COMPANY NAME DOOR LOCATION DATE NOTES INITIAL ...