background image

8371/ 8372 Electromagnetic Lock Installation Instructions 

(Continued)

2

SCS (Security Condition Sensor) with LED

This feature can detect the quality of the locking bond between the 

surface of the magnet and the armature plate. The sensitivity of this 

feature is such that a foreign object with a thickness of .007” (.18mm) 

is sufficient to allow the sensor to detect a problem.

Due to the sensitivity of this feature and the necessity to maintain a 

reliable locking bond, these surfaces must be kept free of contaminating 

materials. Both the lock surface and the armature plate must be cleaned 

periodically with a non-abrasive cleanser. Alignment of armature plate 

and magnet is required to ensure proper function of sensor.

DSS (Door Status Sensor)

The DSS option monitors the position of the door upon which the lock 

is installed. A SPST reed switch eliminates the need for extra sensors 

to be installed on the door for notification of security or access control 

systems. The DSS option comes with a magnet pre-installed into the 

lock armature plate for signaling the reed switch in the housing when 

the door is closed. Care should be taken during the final testing of the 

lock to ensure that the DSS option is operating in the desired manner.

Magnet power from

Power Supply

+12/24VDC input

- (Ground)

Jumper

12VDC

Jumper

24VDC

(preset)

Power Input Requirements

MODEL 

12VDC 

24VDC

8371 

0.52A 

0.26A

8372 

1.04A 

0.52A

2 x BLUE LEADS Normally Open

FOR MODELS WITH OPTIONAL DSS

contacts are rated 0.20A@12VDC 
and 0.12A @ 24VDC

shown with Door Open

Wiring : For Unmonitored or DSS Sensor Models

12

24

12

GB

R

LED

R

B

G

HR

-

VDC

C

NC

NO

GB

R

LED

Voltage Jumper

s

}

Optional SCS Sensor

SPDT Output contacts rated 

for maximum 1.00 Amperes 

at 24VDC

Common
Normally Closed

Normally Open

2 x BLUE LEADS Normally Open

Optional DSS

 contacts rated at 

0.20A@12VDC and 0.12A @ 24VDC

Both the SCS and DSS options are shown 
with Door Open

Tip:

 Fully depress orange tab to insert wires

-

LED

RB

G

GB

R

LED

12

24

12

R

B

G

HR

VDC

C

NC NO

Voltage Jumper

s

}

Optional SCS Sensor

SPDT Output contacts rated 

for maximum 1.00 Amperes 

at 24VDC

Common

Normally Closed

Normally Open

Optional DSS

 contacts rated at 

0.20A@12VDC and 0.12A @ 24VDC

Both the SCS and DSS options are shown 
with Door Open

Tip:

 Fully depress orange tab to insert wires

2 x BLUE LEADS Normally Open

8371 SCS and 8372 SCS 

Side 1

8372 SCS 

Side 2

Wiring : For SCS or SCS/DSS Combination Models

Green LED indicates door locked with secure bond. 

Red LED indicates door unlocked or poor bond.

UL 294 Performance Ratings:
Access Control Line Security : Level I
Destructive Attack : Level I
Endurance : Level IV
Standby Power : Level I

Summary of Contents for 8371

Page 1: ...t must be installed according to all applicable building and life safety codes 2 Due to the variety of mounting configurations available with this product a survey and assessment of the physical area in which the product will be installed must be performed 3 The door frame must be inspected and deemed structurally sound prior to installation of the electromagnetic lock The structural integrity of ...

Page 2: ...he desired manner Magnet power from Power Supply 12 24VDC input Ground Jumper 12VDC Jumper 24VDC preset Power Input Requirements MODEL 12VDC 24VDC 8371 0 52A 0 26A 8372 1 04A 0 52A 2 x BLUE LEADS Normally Open FOR MODELS WITH OPTIONAL DSS contacts are rated 0 20A 12VDC and 0 12A 24VDC shown with Door Open Wiring For Unmonitored or DSS Sensor Models 12 24 12 G B R LED R B G HR VDC C NC NO G B R LED...

Page 3: ...unting bracket 8371 Lock Dimensions 1 D x 1 7 8 W x 9 3 8 L 25 x 48 x 238mm 8372 Lock Dimensions 1 D x 1 7 8 W x 18 3 4 L 25x 48 x 476mm Armature Plate Dimensions 1 2 D x 1 1 2 W x 7 1 4 L 13 x 38 x 185mm Electrical Voltage 12VDC or 24VDC Current Max 0 52A at 12VDC each lock on 8372 model Max 0 26A at 24VDC each lock on 8372 model SCS Output Relay SPDT relay Contacts rated at 1 0A 24VDC DSS Reed S...

Page 4: ... 4 thick glass doors Used to provide extra mounting space in a hollow metal or wood frame where the door stop of the frame is not thick enough to allow a lock to be installed Available in several different heights and widths For use when an obstruction in the door prevents the installation of the armature plate at a proper height If the armature plate needs to be lowered then a spacer bar can be u...

Page 5: ...two separate categories for use in both the United States and Canada Auxiliary Lock The GWXT fire listing qualifies these for use with UL Classified fire doors maximum 4 in width and 8 in height The 8371 and 8320 are rated up to and including 1 hr Special Locking Arrangement Component Additionally these products are qualified components for the purpose of locking outward swinging exit doors agains...

Page 6: ... Wire Run ft Load Current 24V 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A 100 24 20 18 18 16 16 14 12 150 22 18 16 16 14 14 12 10 200 20 18 16 14 14 12 12 10 250 18 16 14 14 12 12 12 10 300 18 16 14 12 12 12 10 400 18 14 12 12 10 10 500 16 14 12 10 10 750 14 12 10 10 1000 14 10 10 1500 12 10 Total One Way Length of Wire Run ft Load Current 12V 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A 100 20 18 16 14 14 12 ...