Product Mounting Accessories Guide

Used in a narrow head jamb situation or for center-hung doors. 

Any place where there is insufficient frame depth to mount the lock.

The Early Warning uses the same angle bracket as the RCI 

standard 8310.

Available in several different sizes and finishes. 

Required wherever there is insufficient space on the frame header to 

mount the lock.  The lock mounts to the underside of the “L” bracket 

and the “L” bracket then gets mounted to the doorframe.

Available in several different sizes and finishes. 

 

  

Used to provide extra mounting space in a hollow metal or wood 

frame where the door stop of the frame is not thick enough to allow 

a lock to be installed.

The Early Warning uses the same filler bars as the RCI  

standard 8310.

Available in several different widths.

 

  

 

For use when an obstruction in the door prevents the installation of 

the armature plate at a proper height. If the armature plate needs 

to be lowered then a spacer bar can be used to lower the lock from 

the frame.

Available in several different thickness.

  

For use with doors that do not permit the armature plate to be 

mounted low enough to meet the magnet surface. Eg: Some 

aluminum framed commercial glass doors. The armature holder can 

be mounted to whatever frame is available and the armature plate in 

turn mounted to the holder.

Available in both flat (shown) and pocket styles. 

Angle Bracket 

“L” Bracket 

Filler Bars 

 

Spacer Bars 

Armature Holder

            PART 

 

 

 

 

USAGE   

 

 

                  EXAMPLE

EW8310 Early Warning Electromagnetic Lock

Installation Instructions 

(Continued)

7

Accessories may impact holding force. 

(Separate installation instructions provided with accessories.)

Summary of Contents for EW8310

Page 1: ...n of this product should be done by an experienced installer with knowledge of this product 12 A mechanical latching device is recommended in conjunction with the Early Warning 8310 to maintain security during a power failure NOTE It is highly recommended that thread locking compound be applied to all screws during installation to reduce chance of screws loosening over extended time PLEASE DELIVER...

Page 2: ...second Remote Alarm Period if the pressure has been withdrawn the Local Alarm relay will return to the normal condition The light panel however will continue to flash red and green until reset The Remote Alarm relay will remain off until reset If pressure is reapplied to the door the system goes directly to the 30 second Remote Alarm Period activation of Local Alarm Relay If the door is forced ope...

Page 3: ...NG MARKS FOR CANADA AND THE U S These Marks are registered by Underwriters Laboratories Inc The minimum height of the registered trademark symbol shall be 3 64 of an inch When the overall diameter of the UL Mark is less than 3 8 of an inch the trademark symbol may be omitted if it is not legible to the naked eye The font for all letter forms is Helvetica Condensed Black except for the trademark sy...

Page 4: ...power wires black is negative and Red is positive Remote A Purple is common C Orange is normally closed NC Blue is normally open NO Local Grey is common C Green is normally open NO Pink is normally closed NC ORDER SEPARATELY RCI 960 MO RECOMMENDED ORDER SEPARATELY OPTIONAL REQUEST TO EXIT SWITCH RCI 970 0R 975 RECOMMENDED NC PINK NO GREEN LOCAL COMMON GREY AUDIO SELECT SOUND PATTERNS 7 8 OR 9 ONLY...

Page 5: ...ed by the access control device 2 The access control device must be set for fail safe operation Override Connection for two EW8310 units Reset Connection for two EW8310 units Reset and Override Wiring for Double Doors Diagram reflects status with power on and door opened Override Connection for two EW8310 units Reset Connection for two EW8310 units NOTE By using either remote relay and the local r...

Page 6: ...ices that may be installed Cannot remove the lock mounting bracket from top of magnet for installation Lock is installed but has no holding force at all Lock has enough holding force to lightly hold a screwdriver or set of pliers but door will not lock Lock is operating and locking but the armature plate is humming against the surface of the lock Lock is not releasing immediately upon removal of p...

Page 7: ...filler bars as the RCI standard 8310 Available in several different widths For use when an obstruction in the door prevents the installation of the armature plate at a proper height If the armature plate needs to be lowered then a spacer bar can be used to lower the lock from the frame Available in several different thickness For use with doors that do not permit the armature plate to be mounted l...

Page 8: ...10 1000 14 10 10 1500 12 10 Total One Way Length of 1 4A 1 2A 3 4A 1A 1 1 4A 1 1 2A 2A 3A Wire Run ft 100 20 18 16 14 14 12 12 10 150 18 16 14 12 12 12 10 200 16 14 12 12 10 10 250 16 14 12 10 10 10 300 16 12 12 10 10 400 14 12 10 500 14 10 10 750 12 10 1000 10 1500 10 Load Current 24V Load Current 12V Wire Gauge Chart courtesy of Electronic Locking Devices by John L Schum WIRE GAUGE SELECTIONS 20...

Reviews: