background image

1. Determine the vertical centerline of the door lock face and

the horizontal centerline of the latch.

IMPORTANT

: When determining the horizontal centerline

observe the following:

FOR MORTISE LOCKS

: Align the angled ramps of the lip

bracket with the deadlock trigger of the mortise latch.

FOR CYLINDRICAL LOCKS

: Align the center of the latch with

the center of the strike opening.**

2. Transfer both the horizontal and vertical centerlines to the

doorframe.**

3. Prepare the doorframe for cutting as shown in the

appropriate drawing.

4. If required, install the ‘no weld’ mounting brackets per page 4.

5. Attach the strike faceplate to the lip bracket with the self-

tapping screws provided. (It may be desirable to leave these

screws slightly loose to facilitate insertion into the

doorframe.

6. Connect the incoming wiring from the power supply (see

wiring instructions).

7. Install the door strike in the doorframe using the screws

provided.

E

K

B

A

F

M

G

C

G

D

R

X

C

L

C

L

M

S6504 

Aluminum & Wood Frames, 1-3/16" D

Modular 

AS65

with 

B604

faceplate

MEASUREMENT

FRACTIONAL

INCHES

DECIMAL

INCHES

METRIC

mm

A

1-1/4

1.250

31.75

B

4-7/8

4.875

123.83

C

3-3/8

3.375

85.73

D

1-3/16

1.188

30.16

E

3/8

.375

9.53

F

1/8*

.125*

3.18*

G 1-11/16

1.688

42.86

Vertical

Vertical

Vertical

X

C/L

C/L

C/L

Door

Door

Door

R

5/32

0.156

3.97

K

4-1/8

4.125

104.78

M

12-24

Vertical Centerline

of Door**

I N S T A L L A T I O N

Electric Strikes

6 Series

Instructions

E

K

B

A

F

M

G

C

G

D

R

X

C

L

C

L

M

L6504

Aluminum & Wood Frames, 1-1/16" D

Modular 

AL65

with 

B604

faceplate

MEASUREMENT

FRACTIONAL

INCHES

DECIMAL

INCHES

METRIC

mm

A

1-1/4

1.250

31.75

B

4-7/8

4.875

123.83

C

3-3/8

3.375

85.73

D

1-3/32

1.094

27.78

E

3/8

.375

9.53

F

1/8*

.125*

3.18*

G 1-11/16

1.688

42.86

Vertical

Vertical

Vertical

X

C/L

C/L

C/L

Door

Door

Door

R

5/32

0.156

3.97

K

4-1/8

4.125

104.78

M

12-24

Vertical Centerline

of Door**

NOTE

: Specifications subject to change without notice.

*

Dimension F

is measured from face of mounting tab to face of frame and equates to the thickness of the faceplate.

**

Dimension X

on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps will be neces-

sary to ensure proper operation of the deadlocking pin. Measure the thickness of the deadlocking pin and add this thickness to Dimension X to relocate the
vertical centerline an appropriate distance on the frame.

For wood frame door installations, substitute #12 wood screws for dimension M.

©2008 RUTHERFORD CONTROLS INT’L CORP. WWW.RUTHERFORDCONTROLS.COM

USA: 2697 INTERNATIONAL PARKWAY, PKWY 5, VIRGINIA BEACH, VA 23452 • CANADA: 210 SHEARSON CRESCENT, CAMBRIDGE, ON  N1T 1J6 

PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-MAIL: SALES@RUTHERFORDCONTROLS.COM 

IS6A

PCN080047

P09/08DA

The L65 Low Profile version accepts 1/2” or 5/8” latch projection (perfect for narrow stile aluminum frames). The S65 Standard 

version is ideal when you require 3/4" latch projection. 

 

Summary of Contents for L65 Series

Page 1: ... I O N Electric Strikes 6 Series Instructions E K B A F M G C G D R X C L C L M L6504 Aluminum Wood Frames 1 1 16 D Modular AL65 with B604 faceplate MEASUREMENT FRACTIONAL INCHES DECIMAL INCHES METRIC mm A 1 1 4 1 250 31 75 B 4 7 8 4 875 123 83 C 3 3 8 3 375 85 73 D 1 3 32 1 094 27 78 E 3 8 375 9 53 F 1 8 125 3 18 G 1 11 16 1 688 42 86 Vertical Vertical Vertical X C L C L C L Door Door Door R 5 32...

Page 2: ...enterline of Door F C G G A M B K E X R D F C L M C L L6507 Aluminum Wood Frames 1 1 16 D Modular AL65 with B607 faceplate A 1 1 4 1 250 31 75 B 6 7 8 6 875 174 63 C 3 3 8 3 375 85 73 D 1 3 32 1 094 27 78 E 3 8 0 375 9 53 F 1 8 125 3 18 G 1 11 16 1 688 42 86 Vertical Vertical Vertical X C L C L C L Door Door Door R 5 32 156 3 97 K 6 1 8 6 125 155 58 M 12 24 MEASUREMENT FRACTIONAL INCHES DECIMAL IN...

Page 3: ...or Door Door R 5 32 156 3 97 K 7 7 16 7 438 188 91 M 12 24 Vertical Centerline of Door X E K B R M F D G G C A M L6508 Aluminum Wood Frames 1 1 16 D Modular AL65 with B608 faceplate MEASUREMENT FRACTIONAL INCHES DECIMAL INCHES METRIC mm A 1 7 16 1 438 36 51 B 7 15 16 7 938 201 61 C 3 3 8 3 375 85 73 D 1 3 32 1 094 27 78 E 1 4 0 250 6 35 F 1 8 125 3 18 G 1 11 16 1 688 42 86 Vertical Vertical Vertic...

Page 4: ...ory installed mounting tabs for electric strike installation 1 Prepare the frame as shown in the approximate drawing Fasten the mounting bracket to the faceplate of the strike selecting the appropriate shims for the installation 2 Using the assembled strike and brackets as a template place against the frame and mark the mounting hole locations Remove and drill a 3 16 hole in frame for each mountin...

Page 5: ...cked screw fully clockwise Fig 3 Lip bracket adjustment Wiring Instructions Use the appropriate wire harness supplied 12V for 12VDC 12 24VAC 24V for 24VDC only Attach the red wire to positive of the power supply Attach the black wire to the negative of the of the power supply see Fig 4 If using AC power polarity is not observed NOTE If a suppression diode is required for access control observe pro...

Page 6: ...rrect voltage DC power supply Insert has a burnt smell Improper voltage Confirm that you have the correct output voltage at the power supply Improper application A strike connected to an AC power supply will buzz unless a rectifier is installed Improper installation Confirm that the correct connector was used when installing the strike 12V for 12VDC 12 24VAC 24V for 24VDC only Confirm that all con...