background image

6 Series Installation Instructions 

(Continued)

C

G

G

F

M

A

D

E

K

B

X

M

F

C

L

C

L

S6514 

Hollow Metal & Wood Frames, 1-3/16" D

Modular 

AS65

with 

B614

faceplate

MEASUREMENT

FRACTIONAL

INCHES

DECIMAL

INCHES

METRIC

mm

A

1-1/4

1.250

31.75

B

4-7/8

4.875

123.83

C

3-3/8

3.375

85.73

D

1-3/16

1.188

30.16

E

3/8

.375

9.53

F

1/8*

.125*

3.18*

G

1-11/16

1.688

42.86

Vertical

Vertical

Vertical

X

C/L

C/L

C/L

Door

Door

Door

K

4-1/8

4.125

104.78

M

12-24

Vertical Centerline

of Door**

C

G

G

F

M

A

D

E

K

B

X

M

F

C

L

C

L

L6514 

Hollow Metal & Wood Frames, 1-1/16" D

Modular 

AL65

with 

B614

faceplate

MEASUREMENT

FRACTIONAL

INCHES

DECIMAL

INCHES

METRIC

mm

A

1-1/4

1.250

31.75

B

4-7/8

4.875

123.83

C

3-3/8

3.375

85.73

D

1-3/32

1.094

27.78

E

3/8

.375

9.53

F

1/8*

.125*

3.18*

G

1-11/16

1.688

42.86

Vertical

Vertical

Vertical

X

C/L

C/L

C/L

Door

Door

Door

K

4-1/8

4.125

104.78

M

12-24

Vertical Centerline

of Door**

X

E

K

B

R

M

F

D

G

G

C

A

M

S6508 

Aluminum & Wood Frames, 1-3/16" D

Modular 

AS65

with 

B608

faceplate

MEASUREMENT

FRACTIONAL

INCHES

DECIMAL

INCHES

METRIC

mm

A

1-7/16

1.438

36.51

B

7-15/16

7.938

201.61

C

3-3/8

3.375

85.73

D

1-3/16

1.188

30.16

E

1/4

0.250

6.35

F

1/8*

.125*

3.18*

G

1-11/16

1.688

42.86

Vertical

Vertical

Vertical

X

C/L

C/L

C/L

Door

Door

Door

R

5/32

.156

3.97

K

7-7/16

7.438

188.91

M

12-24

Vertical Centerline

of Door**

X

E

K

B

R

M

F

D

G

G

C

A

M

L6508 

Aluminum & Wood Frames, 1-1/16" D

Modular 

AL65

with 

B608

faceplate

MEASUREMENT

FRACTIONAL

INCHES

DECIMAL

INCHES

METRIC

mm

A

1-7/16

1.438

36.51

B

7-15/16

7.938

201.61

C

3-3/8

3.375

85.73

D

1-3/32

1.094

27.78

E

1/4

0.250

6.35

F

1/8*

.125*

3.18*

G

1-11/16

1.688

42.86

Vertical

Vertical

Vertical

X

C/L

C/L

C/L

Door

Door

Door

R

5/32

.156

3.97

K

7-7/16

7.438

188.91

M

12-24

Vertical Centerline

of Door**

NOTE

: Specifications subject to change without notice.

*

Dimension F

is measured from face of mounting tab to face of frame and equates to the thickness of the frame material.

**

Dimension X

on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps will be neces-

sary to ensure proper operation of the deadlocking pin. Measure the thickness of the deadlocking pin and add this thickness to Dimension X to relocate the
vertical centerline an appropriate distance on the frame.

For wood frame door installations, substitute #12 wood screws for dimension M.

©2008 RUTHERFORD CONTROLS INT’L CORP. WWW.RUTHERFORDCONTROLS.COM

USA: 2697 INTERNATIONAL PARKWAY, PKWY 5, VIRGINIA BEACH, VA 23452 • CANADA: 210 SHEARSON CRESCENT, CAMBRIDGE, ON  N1T 1J6 

PHONE • 1.800.265.6630 • 519.621.7651 • FAX: 1.800.482.9795 • 519.621.7939 • E-MAIL: SALES@RUTHERFORDCONTROLS.COM 

3

Summary of Contents for L65 Series

Page 1: ... I O N Electric Strikes 6 Series Instructions E K B A F M G C G D R X C L C L M L6504 Aluminum Wood Frames 1 1 16 D Modular AL65 with B604 faceplate MEASUREMENT FRACTIONAL INCHES DECIMAL INCHES METRIC mm A 1 1 4 1 250 31 75 B 4 7 8 4 875 123 83 C 3 3 8 3 375 85 73 D 1 3 32 1 094 27 78 E 3 8 375 9 53 F 1 8 125 3 18 G 1 11 16 1 688 42 86 Vertical Vertical Vertical X C L C L C L Door Door Door R 5 32...

Page 2: ...enterline of Door F C G G A M B K E X R D F C L M C L L6507 Aluminum Wood Frames 1 1 16 D Modular AL65 with B607 faceplate A 1 1 4 1 250 31 75 B 6 7 8 6 875 174 63 C 3 3 8 3 375 85 73 D 1 3 32 1 094 27 78 E 3 8 0 375 9 53 F 1 8 125 3 18 G 1 11 16 1 688 42 86 Vertical Vertical Vertical X C L C L C L Door Door Door R 5 32 156 3 97 K 6 1 8 6 125 155 58 M 12 24 MEASUREMENT FRACTIONAL INCHES DECIMAL IN...

Page 3: ...or Door Door R 5 32 156 3 97 K 7 7 16 7 438 188 91 M 12 24 Vertical Centerline of Door X E K B R M F D G G C A M L6508 Aluminum Wood Frames 1 1 16 D Modular AL65 with B608 faceplate MEASUREMENT FRACTIONAL INCHES DECIMAL INCHES METRIC mm A 1 7 16 1 438 36 51 B 7 15 16 7 938 201 61 C 3 3 8 3 375 85 73 D 1 3 32 1 094 27 78 E 1 4 0 250 6 35 F 1 8 125 3 18 G 1 11 16 1 688 42 86 Vertical Vertical Vertic...

Page 4: ...ory installed mounting tabs for electric strike installation 1 Prepare the frame as shown in the approximate drawing Fasten the mounting bracket to the faceplate of the strike selecting the appropriate shims for the installation 2 Using the assembled strike and brackets as a template place against the frame and mark the mounting hole locations Remove and drill a 3 16 hole in frame for each mountin...

Page 5: ...cked screw fully clockwise Fig 3 Lip bracket adjustment Wiring Instructions Use the appropriate wire harness supplied 12V for 12VDC 12 24VAC 24V for 24VDC only Attach the red wire to positive of the power supply Attach the black wire to the negative of the of the power supply see Fig 4 If using AC power polarity is not observed NOTE If a suppression diode is required for access control observe pro...

Page 6: ...rrect voltage DC power supply Insert has a burnt smell Improper voltage Confirm that you have the correct output voltage at the power supply Improper application A strike connected to an AC power supply will buzz unless a rectifier is installed Improper installation Confirm that the correct connector was used when installing the strike 12V for 12VDC 12 24VAC 24V for 24VDC only Confirm that all con...

Reviews: