background image

Instruction Manual

Innovative DisplayWorks

RCM-77

2

3

PARTS AND IDENTIFICATION

1

2

6

5

4

7

17

16

8

18

19

14

10

12

11

26

25

24

23

22

21

20

15

3

9

13

27

12

12

1.  Barrel Cabinet

2. Transformer

3.  Transformer Box

4.  Drain Tube

5.  Drip Pan

6.  Fan of Condenser

7. Compressor

8.  Compressor Base

9.  Thermostat Box Cover

10. Thermostat

11. Support

12.  Wheels (Swivel) (3)

13.  Wheel (Locking)

14.  Power Line

15.  Retaining Clip of Line

16.  Connecting Line for Thermostat 

17.  Connecting Line for Transformer

18.  Connecting Line for Fan

19.  Ground Wire

20. Lid

21. Basket

22.  Baffle of Inner Fan

23.  Inner Fan Cover 

24.  Inner Fan 

25.  Inner Rim

26.  Stainless Steel Liner

27.  Cooling Packs (16)

SAFETY INSTRUCTIONS

When using this appliance, always follow the basic safety precautions:

1.  Read the entire Userʼs Manual before operating this appliance.

2.  Use this appliance only for its intended purpose as described in this Userʼs Manual.

3.  This cooler must be properly installed in accordance with the installation instructions before being used.  See grounding 

instructions.

4.  IDW requires that a dedicated circuit be used for the unit.  Failure to do so voids warranty.

5.  Never unplug your cooler by pulling on the power cord.  Always grasp the plug fi rmly and pull it straight out from the 

outlet.

6.  Unplug your cooler before cleaning or making any repairs. 

Note:  If for any reason this product requires service, we strongly recommend that a certifi ed technician perform the service.

7.  When disconnecting the power source, wait at least 5 minutes to reconnect the power to avoid damage to the compressor 

and the cooling system.

8.  Immediately repair or replace all electrical cords that have become frayed or otherwise damaged.  Do not use a cord that 

shows cracks or abrasion damage along its length, the plug or the connector end.

9.  Do not operate or store your cooler near or around explosive fumes, gasoline or other fl ammable vapors and liquids.

10.   Do not use fl ammable liquids to clean unit.

11.  Setting the temperature control to the 0 position does not remove power to the light circuit, perimeter heaters, or 

evaporator fans.

12.  Do not adjust the temperature control.  The temperature control is factory set between levels 4 and 5 for maximum 

performance.

  

IMPORTANT!

Please Save These Instructions

For Proper Disposal of the Refrigerator!

PRE-CAUTION, NON-OPERATING COOLERS SHOULD HAVE:

1.  Door removed

2.  Shelves kept in place in order to prevent any small child from climbing inside cooler

FOR PROPER DISPOSAL OF COOLER:

 Distributors / retailers need to contact a qualifi ed service technician:

1.  To recover all refrigerant from the cooler 

2.  To remove the compressor or remove the oil from the compressor 

Then the distributor / retailer can contact their local metal recycling center to pick up the remaining cabinet, shelves, etc. 

By law, disposal of hazardous wastes may be subject to fi nes and imprisonment under the provisions of the environmental 

regulations. For more information please visit: http://www.epa.gov/osw/hazard/index.htm

Summary of Contents for RCM-77-N14NF

Page 1: ...G Series Cooler Instruction Manual Manual is for the following models RCM 77 N14NF RCM 77 N14NG RCM 77 N14NI RCM 77 N14NL RCM 77 RECHARGE COLD MERCHANDISER ...

Page 2: ...r Keep your receipt with this manual for future warranty service Model Serial Date of Purchase TABLE OF CONTENTS Parts and Identification 2 Safety Instructions 3 Preparation 4 Location 5 Installation and Operation 5 Clamp Installation 5 Beverage Storage 6 Maintenance 6 Changing Graphics 7 Cleaning 8 Troubleshooting 9 Circuit Diagram 10 1 Manual is for the following models RCM 77 N14NF RCM 77 N14NG...

Page 3: ...hat a certified technician perform the service 7 When disconnecting the power source wait at least 5 minutes to reconnect the power to avoid damage to the compressor and the cooling system 8 Immediately repair or replace all electrical cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length the plug or the connector end 9 Do not op...

Page 4: ... of the cooler must be done according to applicable local codes or equivalent Ambient Environment Place cooler on an even surface to reduce vibration and noise To transport do not tilt the cooler beyond a 45 degree angle Do not place cooler in direct sunlight or near any heat sources Do not place cooler in environment temperatures that exceed 109 F Do not place cooler in below normal temperatures ...

Page 5: ...Remove the baffler from cooler 3 Using a Phillips screwdriver unscrew the 4 screws at the base of the cooler 1 Remove the basket from the inside of the cooler 5 Lay the body of the cooler on its side to access components 6 To re assemble the cooler align the notch at base of the body with the cooler cord Then reverse steps 1 5 4 The body of the cooler can now be worked free from the frame 2 Wedge ...

Page 6: ... This may be due to a high indoor humidity or the coolers temperature is set too low Wipe the door dry with a towel Prior to calling service check the following Issues Solutions Cooler is not working properly Please check power supply Check the electrical outlet for power and that the plug is properly inserted Check to see if the circuit breaker is tripped or the fuse is blown Check if the condens...

Page 7: ...Instruction Manual Innovative DisplayWorks RCM 77 10 RCM 77 CIRCUIT DIAGRAM ...

Page 8: ...Innovative DisplayWorks Inc To locate the distributor in your area go to http www idw global contact distributors ...

Reviews: