CLEANING

  Unplug the cooler prior to cleaning.  

  Unplug the cooler at the electrical outlet; never pull the service cord.

  Do not use sharp or pointed objects for cleaning.  

  Do not spray water directly onto cooler, and do not use hard or steel brushes to clean the cooler.

  Clean the inside cabinet of the cooler with a clean, damp cloth or with mild soap.

  Avoid damaging the cooler by using only non-abrasive cleaning products.  Do not use organic solvents, boiling water, 

washing powder or acid while cleaning.

If the cooler is unused for a long period of time, unplug the electrical cord, follow cleaning instructions, and open or remove the lid.

MOVING THE COOLER

  Remove all product from the unit.  

  Secure all loose parts inside the cooler.

  Tape the door shut.  

  Ship the cooler in an upright position.

REFRIGERATION

  The RCM-77 Electric Impulse Cooler utilizes R134a refrigerant. 

SPECIFICATIONS

Model:

RCM-77 Electric Impulse Cooler

Power Supply (V/Hz):

220-240V/50Hz

Dimension (Diameter x H):

22-1/4” x 33-1/4” 

Box Dimension (Diameter x H):

23” x 34”

Troubleshooting

The following are NOT malfunctions:

Situation

Causes

Liquid fl owing noise within cooler

•  This is the sound of the cooling agent fl owing through the pipes.

Refrigeration system is shutdown for longer periods 

of time while temperature inside is still very low

•  This refrigerator is well insulated and can maintain a relatively ambient 

temperature.

Condensation on glass door

•  This may be due to a high indoor humidity or the coolers temperature is set too 

low. Wipe the door dry with a towel.

Prior to calling service, check the following:.

Issues

Solutions

Cooler is not working properly

Please check power supply:

•  Check the electrical outlet for power, and that the plug is properly inserted.

•  Check to see if the circuit breaker is tripped or the fuse is blown.

•  Check if the condenser is free of dirt and debris.

•  Check for low voltage

Cooler is not keeping product cool

•  Provide ample space between all products to ensure proper circulation of air.

•  Keep unit away from direct sunlight or other heating source.

•  Keep the door closed as often as possible.

•  Be certain the cooler is not touching external objects or walls.

Excessive noise

•  Be certain the cooler is placed on a level surface.

•  Be certain the cooler is not touching external objects or walls.

Compressor turns on and off frequently

•  The room temperature is higher than normal.

•  The door is not closed completely.

•  The door gasket is not sealed properly.

•  There is insuffi cient clearance around the cooler.

•  The thermostat is not set properly.

•  The frequency of cycling will be reduced when all of the product reaches the set 

temperature.

After Sales Service

Information to provide to your qualifi ed service professional:

•  Serial number from the interior wall of the cooler;

•  Coolersʼ installation address and contact information;

•  Installation location hours and operation;

•  Nature of problem;

•  Any reports of power interruptions;

•  Recent service or maintenance completed on the cooler;

•  Has the cooler been relocated from original installation location;

•  Clear access to the cooler;

•  Coolersʼ instruction manual.

Summary of Contents for RCM-77-N14NF

Page 1: ...G Series Cooler Instruction Manual Manual is for the following models RCM 77 N14NF RCM 77 N14NG RCM 77 N14NI RCM 77 N14NL RCM 77 RECHARGE COLD MERCHANDISER ...

Page 2: ...r Keep your receipt with this manual for future warranty service Model Serial Date of Purchase TABLE OF CONTENTS Parts and Identification 2 Safety Instructions 3 Preparation 4 Location 5 Installation and Operation 5 Clamp Installation 5 Beverage Storage 6 Maintenance 6 Changing Graphics 7 Cleaning 8 Troubleshooting 9 Circuit Diagram 10 1 Manual is for the following models RCM 77 N14NF RCM 77 N14NG...

Page 3: ...hat a certified technician perform the service 7 When disconnecting the power source wait at least 5 minutes to reconnect the power to avoid damage to the compressor and the cooling system 8 Immediately repair or replace all electrical cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length the plug or the connector end 9 Do not op...

Page 4: ... of the cooler must be done according to applicable local codes or equivalent Ambient Environment Place cooler on an even surface to reduce vibration and noise To transport do not tilt the cooler beyond a 45 degree angle Do not place cooler in direct sunlight or near any heat sources Do not place cooler in environment temperatures that exceed 109 F Do not place cooler in below normal temperatures ...

Page 5: ...Remove the baffler from cooler 3 Using a Phillips screwdriver unscrew the 4 screws at the base of the cooler 1 Remove the basket from the inside of the cooler 5 Lay the body of the cooler on its side to access components 6 To re assemble the cooler align the notch at base of the body with the cooler cord Then reverse steps 1 5 4 The body of the cooler can now be worked free from the frame 2 Wedge ...

Page 6: ... This may be due to a high indoor humidity or the coolers temperature is set too low Wipe the door dry with a towel Prior to calling service check the following Issues Solutions Cooler is not working properly Please check power supply Check the electrical outlet for power and that the plug is properly inserted Check to see if the circuit breaker is tripped or the fuse is blown Check if the condens...

Page 7: ...Instruction Manual Innovative DisplayWorks RCM 77 10 RCM 77 CIRCUIT DIAGRAM ...