background image

Instruction Manual

Innovative DisplayWorks

RCM-77

10

RCM-77 CIRCUIT DIAGRAM

Summary of Contents for RCM-77-N14NF

Page 1: ...G Series Cooler Instruction Manual Manual is for the following models RCM 77 N14NF RCM 77 N14NG RCM 77 N14NI RCM 77 N14NL RCM 77 RECHARGE COLD MERCHANDISER ...

Page 2: ...r Keep your receipt with this manual for future warranty service Model Serial Date of Purchase TABLE OF CONTENTS Parts and Identification 2 Safety Instructions 3 Preparation 4 Location 5 Installation and Operation 5 Clamp Installation 5 Beverage Storage 6 Maintenance 6 Changing Graphics 7 Cleaning 8 Troubleshooting 9 Circuit Diagram 10 1 Manual is for the following models RCM 77 N14NF RCM 77 N14NG...

Page 3: ...hat a certified technician perform the service 7 When disconnecting the power source wait at least 5 minutes to reconnect the power to avoid damage to the compressor and the cooling system 8 Immediately repair or replace all electrical cords that have become frayed or otherwise damaged Do not use a cord that shows cracks or abrasion damage along its length the plug or the connector end 9 Do not op...

Page 4: ... of the cooler must be done according to applicable local codes or equivalent Ambient Environment Place cooler on an even surface to reduce vibration and noise To transport do not tilt the cooler beyond a 45 degree angle Do not place cooler in direct sunlight or near any heat sources Do not place cooler in environment temperatures that exceed 109 F Do not place cooler in below normal temperatures ...

Page 5: ...Remove the baffler from cooler 3 Using a Phillips screwdriver unscrew the 4 screws at the base of the cooler 1 Remove the basket from the inside of the cooler 5 Lay the body of the cooler on its side to access components 6 To re assemble the cooler align the notch at base of the body with the cooler cord Then reverse steps 1 5 4 The body of the cooler can now be worked free from the frame 2 Wedge ...

Page 6: ... This may be due to a high indoor humidity or the coolers temperature is set too low Wipe the door dry with a towel Prior to calling service check the following Issues Solutions Cooler is not working properly Please check power supply Check the electrical outlet for power and that the plug is properly inserted Check to see if the circuit breaker is tripped or the fuse is blown Check if the condens...

Page 7: ...Instruction Manual Innovative DisplayWorks RCM 77 10 RCM 77 CIRCUIT DIAGRAM ...

Page 8: ...Innovative DisplayWorks Inc To locate the distributor in your area go to http www idw global contact distributors ...

Reviews: