TABLE OF CONTENTS 

PROVIDED IN INSTRUCTIONS. 

 

Page # 1  Introduction. 

 

Page # 2  Installing the 

OMEGA-3v6s 

ESC. 

 

Page # 3  Installing RX into the 

OMEGA-3v6s

 

Page # 4  Setting up the system. 
                   Binding the RX. 

 

Page # 5  Calibrating the system. 

 

Page # 6  Programming the system. 

 

Page # 7  Operating the System. 
                   Speed & Direction control. 
                   Using Sound Trigger functions. 

 

Page # 8  MU’ing Consists of Locos. 
                   Trouble shooting. 

 

PLEASE NOTE. PDF WIRING INSTRUCTIONS ARE HERE: 

 

http://www.rcs-rc.com/pages/instructions

 

 

 

Thank you for purchasing this Microprocessor based 

E

lectronic 

S

peed 

C

ontrol 

(ESC)

 R/C system. 

 

THESE INSTRUCTIONS REFER SPECIFICALLY FOR USE WITH 

THE 

RCS

 TX-20 & TX-21+ HANDPIECES. 

THERE ARE SEPARATE INSTRUCTIONS FOR USE WITH ANY 2.4 

GHz R/C WITH 4 OR MORE CHANNELS.  

THOSE OTHER INSTRUCTIONS REFER SPECIFICALLY TO THE 

SPEKTRUM DX5e 2.4 GHz R/C. 

THEY ALSO APPLY TO THE DX4e, DX6i & PLANET T5.  

N.B. 

YOU CANNOT MIX BRANDS OF R/C.

  

THE 

RCS 

#

OMEGA-3v6s 

SYSTEM IS IN ONE PART WITH 

SERVO LEADS TO PLUG INTO ANY DSM2 COMPATIBLE RX. 

OR

; USE ANY BRAND OF R/C WITH THE ADDITION OF FOUR 

SERVO LEADS CONNECTED TO THE 6 WAY SCREW 
TERMINAL ON THE ESC AND PLUGGED INTO THE 
APPROPRIATE CONNECTIONS ON THE RX. 

 

 

INSTRUCTIONS. 

 

THESE INSTRUCTIONS REFER TO OPERATING PROGRAM 

RCS-v1

ESC’s WITH OPERATING PROGRAM RCS-v1 CAN BE USED WITH ANY STICK TYPE DSM2 TRANSMITTER. 

 

#

OMEGA-3v6s

HAS BEEN CALIBRATED AT THE FACTORY.  ONCE RX IS “BOUND” TO TX THE SYSTEM IS READY TO USE AS IS. 

THERE ARE MANY FEATURES WITHIN THE SYSTEM WHICH CAN BE PROGRAMMED.  YOU WILL NEED TO DOWNLOAD THE FULL 

INSTRUCTION MANUAL FROM THE RCS WEBSITE.  THE PUSHBUTTON ON THE ESC PCB IS ONLY USED FOR PROGRAMMING.  

DO NOT PRESS THE ESC BUTTON DURING OPERATION. 

 

DO N OT CONNECT TO MAINS POWER (110 – 240V AC). 

 

THE

 #

OMEGA-3v6s 

CAN BE USED WITH ANY FILTERED DC SUPPLY SUCH AS BATTERY POWER. 

THEY HAVE CONSTANT BRIGHTNESS DIRECTIONAL LIGHTS & 2 SOUND TRIGGERS. 

 

THE FOLLOWING MAXIMUM VOLTAGES MENTIONED ARE THE 

NOMINAL

 VOLTAGE & TAKE INTO ACCOUNT THAT FULLY 

CHARGED BATTERIES CAN & DO EXCEED THE 

NOMINAL

 VOLTAGE. 

USE 14v – 20v FOR THE

 #

OMEGA-3v6s

.  A high voltage version is available on request. 

 

We tested this system three times during manufacture.  It was working normally when it left our factory. 

If damage in transit has occurred, please return to place of purchase for attention. 

 

THE ESC IS GUARANTEED FOR ONE YEAR. 

 

The solid state motor driver output IC is guaranteed for life. 

 

You will supply a locomotive or trail car, the 14 – 20 volt traction batteries (depending on ESC), a fuse, 

ON-OFF switch and wires where necessary, to connect the ESC to the battery and motor(s). 

Where soldering is necessary, we recommend a low wattage soldering iron and resin core solder. 

 

TO AVOID CONFUSION WITH OTHER OPERATORS, WE SUGGEST YOU MARK THE TX TO 

SHOW WHICH LOCO IT OPERATES. 

 

CAUTION 

 

DO NOT ATTEMPT TO ALTER THE TUNING OF THE RADIO EQUIPMENT. 

DO NOT USE RADIO CONTROL EQUIPMENT IN THUNDERSTORMS. 

 

CHILDREN UNDER 12:       ADULT SUPERVISION RECOMMENDED DURING USE.

 

 

Summary of Contents for OMEGA-3v6s

Page 1: ...AN BE USED WITH ANY STICK TYPE DSM2 TRANSMITTER OMEGA 3v6sHAS BEEN CALIBRATED AT THE FACTORY ONCE RX IS BOUND TO TX THE SYSTEM IS READY TO USE AS IS THERE ARE MANY FEATURES WITHIN THE SYSTEM WHICH CAN...

Page 2: ...eed calibration and making system program changes such as Start Max voltage default direction start system reset sound trigger outputs from momentary to latch ON OFF If you need to calibrate the syste...

Page 3: ...utput overload and short circuit protection built into them it is essential the battery supply be fused for overall system protection See the wiring diagram pages LOCOMOTIVE LIGHTING RCS ESC s have tr...

Page 4: ...l immediately blink three times If LED does not come on within 10 seconds or continues flashing every 2 seconds scanning the bind has failed Switch TX and RX off move them closer together or further a...

Page 5: ...rnal to the loco by adding the separately available plug in P BUTTON 2 1 Turn the TX 21 ON Make sure Throttle knob is set to Min i e fully CCW 2 2 Press and HOLD ESC push button down turn the ESC Rx O...

Page 6: ...Then move the large throttle knob back to zero OFF position i e knob is fully CCW Then press and release the pushbutton on ESC The lights will blink three times and then go to all solid ON i e Neutral...

Page 7: ...EEDING UP 4 3 SLOWING DOWN 4 4 STOPPING above CAUTION During use if the battery voltage drops below 12 volts measured at the ESC IN terminals loss of control may occur The ESC may even suddenly revers...

Page 8: ...TEM ON WHEN THE LOCO IS SWITCHED ON THE PCB LED s DO NOT LIGHT OR BLINK This is most likely caused by the throttle knob not being at MIN Turn the knob fully CCW to MIN WHEN THE LOCO IS SWITCHED ON THE...

Page 9: ......

Page 10: ......

Reviews: