Also, for other sensor and switch, if it change from 1 to 0 ( or 0 to 1) displayed on the panel,
For example:
Enter unit test---> press stop key--->press "0" button,display
"11010111" the seventh one for scan cover sensor is "1" .
If the signal (0 or1) can change, that means the sensor is ok.
means the sensor /switch is ok; Otherwise , the sensor maybe defective.
1.How to enter test mode: Hold down "select" and "0"--> power on
( RD-3108C RD-3208C RD-4019A RD-4029A )
2.How to change the language: Hold down "mode" and "9" ---> power on
3.How to adjust the print area:
Reduce the print area : Hold down "speed -" and numric key (0~9)---> power on
5. How to test the sensor(switch):
You want to know if the scan cover sensor (RD-4019A) is ok:
Enlarge the print area: Hold down "speed +" and numric key (0~9)--->power on
If sucess ,LED displayed : (0-9)
If sucess ,LED displayed : Verify - (0-9)
If sucess , LED Displayed " Unit test "
If sucess, Chinese ----> English / English ---> Chinese
(1) Useful Test
- 26 -
4. How to test the TPH: Enter test mode, Hold down "stop" --> press "print"
(Make sure the master and ink were installed, It will automatically start master-making).
------>
scan cover closed (sensor blocked)
scan cover open (sensro unblocked)