background image

12

 

The hydraulic connection to a refrigeration group 

capable of providing chilled water is essential. In this case, the 

dehumidifier can operate without varying the temperature of 

the treated water with an important increase in yield.

 

It is recommended to install a siphon on the discharge 

line.

 

After filling the system with water it is recommended 

to carefully check the seals, not only at connections but also 

the hydraulic circuit of the machine that might have been 

damaged in transport or on site during installation; and 

in this case, the manufacturer will respond exclusively for 

“factory” defects of the dehumidifier and in any case he does 

not assume responsibility for indirect damages. 

The condensate drain pipes and inlet and outlet 

piping must meet the standards and laws in force 

in the country of use.

 L’allacciamento idraulico ad un gruppo frigo in 

grado di fornire acqua refrigerata risulta indispensabile. 

In tale caso il deumidificatore potrà operare senza 

variare la temperatura dell’aria trattata con un sensibile 

incremento di resa.

 Si consiglia di realizzare un sifone sulla linea di 

scarico.

 Dopo aver riempito d’acqua l’impianto si 

raccomanda di verificare attentamente la tenuta non solo 

dei collegamenti ma anche del circuito idraulico della 

macchina, che potrebbe essersi danneggiato nel trasporto 

o in cantiere durante l’installazione; a tale proposito 

il costruttore risponderà esclusivamente dei difetti “di 

fabbrica” del deumidificatore e in ogni caso non si assume 

nessuna responsabilità per danni indiretti.

Lo scarico condensa e le tubazioni di ingresso e 

uscita devono rispondere alle norme e leggi 

vigenti nel paese di utilizzo.

 2 - 

H

YDRAULIC

 

CONNECTIONS

 

/

 

C

OLLEGAMENTI

 

IDRAULICI

Table

 

C

 - 

Hydraulic connections to effect

Tabella C - Collegamenti idraulici da effettuare

Rif.

Description

 

Descrizione

A

Exit water pre-treatment (1/2’’F) with stop valve 

Uscita acqua pre-trattam. (1/2”F) con valvola di 

intercettazione

B

Exit water post-treatment (1/2’’F) with stop valve 

Uscita acqua post-trattam. (1/2”F) con valvola di 

intercettazione

C

Inlet water pre-treatment (1/2’’F) with holder of flow 

regulator

Ingresso acqua pre-trattam. (1/2”F) con detentore di 

regolazione portata

D

Water inlet post-treatment (1/2’’F) with holder of flow 

regulator

Ingresso acqua post-trattam. (1/2”F) con detentore di 

regolazione portata

E

Discharge Ø 14mm for condensation 

Scarico in gomma ø14 mm per condensa

OK!

Scarico NON in salita!

Discharge NOT in ascent!

Use suitable pipes in terms of flow capacity function: see 

Table

 “I” (“L”)

Utilizzare tubazioni di misura adeguata in funzione delle portate desiderate: vedi

 Tabella  “I” (“L”)

Summary of Contents for RNW 508-CS

Page 1: ...AirHandlingUnits UnitàTrattamento Aria RNW 508 CS TECHNICAL INSTALLATIONMANUAL MANUALETECNICO INSTALLAZIONE Dehumidierhorizontalceilingmounted Deumidificatore orizzontale a soffitto ...

Page 2: ......

Page 3: ...ione diversa DEVE essere preventivamente concordata con l Ufficio tecnico RDZ Se dopo aver disimballato l apparecchiatura si nota una qualsiasi anomalia non utilizzare l apparecchiatura e rivol gersi ad un Centro di Assistenza autorizzato dal Costruttore SAFETY WARNINGS Read this manual carefully before installing and or using the equipment and keep it in an accessible place This equipment constit...

Page 4: ...odotto da parte dell utente comporta l applicazione delle sanzioni previste dalla vigente normativa in materia After installation dispose of the packaging in accordance with the provisions of the regulations in force in the country of use Use original spare parts only disregarding this rule invalidates the warranty The manufacturer declines all responsibility and considers the warranty invalid in ...

Page 5: ...maintenance clean filter Manutenzione ordinaria pulizia filtro 18 Extraordinary maintenance removing fan Manutenzione straordinaria rimozione ventilatore 19 Visual signals Segnalazioni visive 20 Problems Guasti 21 6 TECHNICAL DATA AND PERFORMANCE DATI TECNICI E PRESTAZIONI 21 Safety controls Controlli di sicurezza 22 Components Componenti 22 Acoustical characteristics Caratteristiche acustiche 23 ...

Page 6: ...ed on the Delivery Sheet before countersigning TheCustomer within8days mustnotifytheManufactureronthe entityandtypeofdamagedetectedbypreparingawrittenreport always record the serial number found on the label attached to the side of the machine 1 4 5 OK OK RDZ entro 8 giorni within 8 days 6 2a 2b 3b 3a The packing of the unit must be removed with care avoidingthepossiblecausingof damage to the mach...

Page 7: ... ø 8mm N Air inlet Ingresso aria P Exit dehumidified air Uscita aria deumidificata Q Vent Sfiato B C E G H P I M F D A L N Q Questa macchina per installazione tipica a controsoffitto è destinata alla deumidificazione di ambienti raffreddati a pannelli radianti L utilizzo è raccomandato entro i limiti di funzionamento Per evitare la formazione di condensa i sistemi di raffrescamento radiante incorp...

Page 8: ...soffitto 2 Hydraulic connections Collegamenti idraulici A Water exit pre treatment 1 2 F with stop valve A Uscita acqua pre trattam 1 2 F con valvola di intercettazione B Water exit post treatment 1 2 F with stop valve B Uscita acqua post trattam 1 2 F con valvola di intercettazione C Water inlet pre treatment 1 2 F with holder of flow regulator C Ingresso acqua pre trattam 1 2 F con detentore di ...

Page 9: ...9 MAX 95 MAX 30 C Duct work Canalizzazione Positioning indications Indicazioni di posizionamento OK 1 POSITIONING AND FIXING TO CEILING POSIZIONAMENTO E FISSAGGIO A SOFFITTO ...

Page 10: ... 2 Fixing to ceiling Fissaggio a soffitto 7 5 6 Minimum space allowanceses Distanze minime di rispetto min 2 cm min 40 cm min 30 cm min 10 cm No constraint nessun vincolo Washer Rondella Rubber mounts Gommino antivibrante ...

Page 11: ...11 min 30 cm min 10 cm min 40 cm X X Trap door Botola d ispezione ...

Page 12: ... collegamenti ma anche del circuito idraulico della macchina che potrebbe essersi danneggiato nel trasporto o in cantiere durante l installazione a tale proposito il costruttore risponderà esclusivamente dei difetti di fabbrica del deumidificatore e in ogni caso non si assume nessuna responsabilità per danni indiretti Lo scarico condensa e le tubazioni di ingresso e uscita devono rispondere alle n...

Page 13: ...norme vigenti nel paese di utilizzo Gli interventi elettrici devono essere effettuati da personale qualificato La linea elettrica di alimentazione deve essere protetta da un interruttore differenziale magnetotermico Verificare che la tensione di alimentazione corrispondaaidatinominalidell unità tensione numerodi fasi frequenza riportati sulla targhetta a bordo macchina e nel capitolo 3 Collegament...

Page 14: ...is normally supplied with the connection on the MIN minimum speed red wire white wire which guarantees 500 m h with head of approximately 12 Pa The other speeds can be obtained using the blue or black wires together with the common wire white wire as shown in Table E below Table E Fan speed variation Wires Air Flow Rate red white common 500 m h head 13 Pa blue white common 500 m h head 52 Pa black...

Page 15: ...ARME Il relé di allarme è normalmente aperto in caso di anomalia il contattosichiude E possibilerendereilcontattonormalmente chiuso togliendo il ponticello denominato NC NO sul circuito stampato della scheda FORCING THE UNIT IN VENTILATION MODE ONLY Two terminals are available on the dehumidifier circuit board which allow the unit to be operated in ventilation mode only The closure of the ventilat...

Page 16: ...nzionamento estivo la principale verifica da effettuare riguarda la portata dell acqua di raffreddamento variabile a seconda delle condizioni di funzionamento desiderate vedi Tabella I Nel caso in cui non sia possibile misurare la portata dell acqua verificare tale condizione controllando la temperatura dell aria in mandata accertandosi che ci si trovi nelle condizioni di progetto la macchina sia ...

Page 17: ...raordinaria descritte in questo capitolo DEVONO ESSERE SEMPRE ESEGUITE DA PERSONALE QUALIFICATO Prima di effettuare qualsiasi intervento sull unità o prima di accedere a parti interne assicurarsi di aver tolto l alimentazione elettrica All interno dell unità sono presenti degli organi in movimento Prestare particolare attenzione quando si operi nelle loro vicinanze anche ad alimentazione elettrica...

Page 18: ...18 ORDINARY MAINTENANCE AND FILTERCLEANING MANUTENZIONE ORDINARIA PULIZIA FILTRO 1 3 2 2 1 2 2 3 every 30 days ogni 30 giorni Spento OFF 28 30 29 4 ...

Page 19: ...19 EXTRAORDINARY MAINTENANCE AND FAN REMOVAL MANUTENZ STRAORDINARIA RIMOZIONE VENTILATORE 1 2 Spento OFF ...

Page 20: ...scarico Steady alarm Allarme permanente Room temperature is too low Temperatura ambiente troppo bassa Steady alarm Allarme permanente Refrigerant max pressure block Blocco di massima pressione refrigerante Steady alarm Allarme permanente Supply water temperature is higher than 30 C Temperatura acqua di mandata superiore a 30 C It automatically stops when water temperature is 30 C Si sblocca da sol...

Page 21: ...Electronic control panel is defective Scheda elettronica difettosa Replace electronic control panel Sostituire la scheda elettronica The fan starts but the compressor does not start Il ventilatore si avvia ma il compressore non parte Thermal sensor of compressor has intervened Defective compressor Insufficient flow level or temperature of supply water Termica del compressore intervenuta Compressor...

Page 22: ...a temperatura acqua sonda temperatura evaporatore Attivazione della funzionalità di deumidificazione L attivazione della funzionalità di deumidificazione avviene attraverso la chiusura dei morsetti relativi al consenso esterno umidostato vedi cap 3 Collegamenti elettrici In fase di avviamento l unità attiva in sequenza il ventilatore e dopo un certo ritardo il compressore Il compressore e quindi l...

Page 23: ... LIVELLI DI POTENZA SONORA Speed 1 dB Velocità 1 dB Speed 2 dB Velocità 2 dB Speed 3 dB Velocità 3 dB Speed 1 dB Velocità 1 dB Speed 2 dB Velocità 2 dB Speed 3 dB Velocità 3 dB 100 43 0 48 4 51 2 52 5 57 8 60 7 125 40 4 45 8 48 7 46 2 51 5 54 5 160 47 2 51 3 53 5 50 6 54 7 56 9 200 42 4 48 7 51 6 47 5 53 7 56 6 250 38 3 44 0 46 6 41 9 47 7 50 3 315 38 4 44 0 46 7 41 7 47 3 50 0 400 40 8 46 7 49 4 ...

Page 24: ...tivo è di 25 C Al di sopra di 30 C il compressore viene escluso lasciando in funzione solamente il ventilatore Tra i 30 e 60 C è possibile attivare la sola ventilazione per un uso invernale dell apparecchio Con temperature dell acqua superiori a 60 C l apparecchio potrebbe danneggiarsi È importante fare in modo che le unità operino nei limiti riportati Al di fuori di tali limiti non sono garantiti...

Page 25: ...con immissione di calore sensibile la portata massima d acqua complessiva alle batterie è di 8 8 litri minuto Parzializzando la portata alla batteria di postrattamento con una valvola di taratura si può ridurre o annullare l apporto sensibile di potenza frigorifera mantenendo elevata la resa in deumidificazione Table I Power and cooling performance in dehumidification Tabella I Potenza frigorifera...

Page 26: ... 12 0 05 0 25 0 04 15 6 2 8 1 33 0 56 1 66 0 17 0 23 0 05 24 55 7 3 1 5 1 65 0 41 1 68 0 09 0 38 0 07 7 6 2 8 2 04 0 87 2 54 0 27 0 37 0 07 15 3 1 5 1 03 0 00 0 87 0 00 0 16 0 00 15 6 2 8 1 24 0 00 1 12 0 00 0 12 0 00 65 7 3 1 5 1 47 0 79 1 81 0 21 0 45 0 10 7 6 2 8 1 89 1 38 2 84 0 45 0 43 0 09 15 3 1 5 1 00 0 05 0 87 0 00 0 18 0 02 15 6 2 8 1 17 0 20 1 21 0 05 0 16 0 03 In Table M values are sup...

Page 27: ...tanteindicano le perdite di carico sulle batterie ad acqua di pretrattamento e postrattamentodell arianeldeumidificatore Ildeumidificatore è predisposto con attacchi esterni separati per le batterie di pretrattamento e postrattamento È possibile quindi alimentare le batterie separatamente con due linee di adduzione indipendenti o collegarle in parallelo in prossimità del deumidificatore La partico...

Page 28: ...e della prevalenza disponibile al ventilatore dell apparrecchiatura L eventuale canalizzazione del deumidificatore deve essere dimensionata in funzione di questo parametro La prevalenza disponibile è espressa al variare della portata dell aria portata nominale 500 m3 h e nelle tre possibili velocità impostabili Di fabbrica il ventilatore dell apparecchiatura è impostato alla velocità media MED Ven...

Page 29: ...29 NOTES ANNOTAZIONI ...

Page 30: ...30 NOTES ANNOTAZIONI ...

Page 31: ......

Page 32: ...9100118 05 04 2016 bit ly rdzwebsite ...

Reviews: