Wire the safeguard latching system. You can wire a button or switch to the latch release
pins to control the latching mechanism. Or you can jumper the latch release inputs so the
safeguard will auto reset when you close the fence (shown in the table).
EPSON Emergency
Connector
External 24V Power
Supply
Fence Device
Function
24V
Fence Contact
11
Safety Door Input 1
Pin 7
Fence Contact
12
Safety Door Input 1
24V
Fence Contact
11
Safety Door Input 1
Pin 8
Fence Contact
12
Safety Door Input 1
Pin 18
24V
Latch Release Input
(Jumpered)
Pin 19
24V
Latch Release Input
(Jumpered)
Pin 20
24V
Safety Door Input 2
(Jumpered)
Pin 21
24V
Safety Door Input 2
(Jumpered)