ERROR RECOVERY
Some errors are currently not recoverable from Forge/OS. One such error is Error 4066:
"Motion Command was attempted in the prohibited area depended on joint combination." This
error occurs when you move the robot outside of its joint limits.
In these situations, the robot is not movable in Forge/OS or in the EPSON RC+ Robot
Manager. If this is the case, use the following instructions to recover your robot to an
operable state.
Restart EPSON RC+ in Program Mode by completing the steps below.
Close EPSON RC+.
1
On startup, select the
Change To Program Mode
button.
2
1
VERSION 1.0.1