24-volt accessories and peripherals can be powered to terminals 50 and 51
ACCESSORY CONNECTIONS
TERMINAL
NAME
DESCRIPTION
50
-24V
Accessory power negative common
51
+24V
Accessory power positive
52
+24V -Safe
Positive power when door is not closed
The Thalia board has two auxiliary outputs.
•
The first (20 and 21) is a 24-volt, courtesy light output that will activate
upon activation of the door and will remain on for 90 seconds once
the door is closed
•
The second output labeled “Aux 3” (26 and 27) is a defaulted as a
second channel radio receiver output. This can be programmed to
perform any of the following functions under “Logic” menu:
AUXILIARY OUTPUTS
RANGE VALUE
FOR “AUX 3:
FUNCTION
DESCRIPTION
0
2nd channel receiver output
Output activate when transmitter activates
the 2nd channel
1
Door open light
Output activate when door is not closed.
Flashes while closing
2
Courtesy light
Output activate during and for 90 seconds
after operation
3
Door not closed
Output activate until close limit is reached
4
Start of cycle
Output activate for 1 second at the
beginning of each cycle
5
Door open alarm
Output activate if door is help open for
more than double the timer to close time
6
Door running
Output active while motors are powered
7
Solenoid lock
Output active for 2 seconds at the
beginning of open cycle
8
Magnetic Lock
Output active when door is closed
16 PR
OGRAMMING FEA
TURES