7
SAFETY INSTRUCTIONS
(continued)
• Ensure 4m
3
of air is supplied for each kW of rated performance. For this fireplace the room
should be at least 32m
3
. If the room is smaller than this then sufficient air supply can be
secured by opening doors to adjoining rooms or installing vents with free area of at least
150cm
2
.
• Ensure clearances from combustible surfaces are maintained in accordance with the drawings
on page 5.
• The fire should never be modified under any circumstances.
• In the event of any flue fire, immediately close all the openings of the appliance and call the fire
brigade. Never try to extinguish the fire with water.
• Thereafter, always have the flue inspected by a qualified technician.