生活美好,臂不可少
http://www.realman-robotics.com
65
Fig. 8-69 Force control command.
Sensor option
:
Sensors include 1-axis force sensor and 6-axis force sensor.
Coordinate system option
:
To choose the force control reference coordinate system.
Hybrid force-position control or force-location mix control:
The direction and force
of the hybrid force-position control can be set. The direction of the one-axis force sensor
is the Z direction, and the six-axis force sensor can choose one of the directions in
X\Y\Z\Rx\Ry\Rz.
Turn off hybrid force-position control or force-location mix control:
After checking
the hybrid force-position control, the subsequent movement command in the program
will no longer use the hybrid force-position control mode.
Note: 1. Waypoint controlled by hybrid force-position must record its
parameters through the Cartesian coordinate system. That is, it must not contain
MOVEJ command.
2. RML63-B robot does not support force control command, if you add force
control command, there will show a data error prompt at the corresponding line.
3. The previous waypoint of the force control should be consistent with the first
waypoint of the force control, and wait for at least 1s before opening the force
control (refer to the program example).