REBOTEC /
BA-Nr.: 02.07.081/2021-10-A01
- 5 -
EN
•
Patients who are prone to uncontrolled actions or
movements must be supervised when using the
chair.
•
The chair must
only
be moved on a slope or incline
with the help of a caregiver. Generally, on an uphill
slope the chair should be pushed forward and on
a downhill slope it should be pulled backward.
Caution: Danger of slipping!
•
Before use, check that the seat surfaces are firmly
clamped in the seat frame.
•
Always lock
at least
2 parking brakes on the
wheels before using the chair to prevent the chair
from rolling away.
•
When sitting down, do not sit on the front edge of
the seat or on the seat cushion, but take up the
entire seat surface.
Caution: Danger of tipping over!
•
The chair must only be pushed by the push handle
(backrest).
•
The footrests must be swivelled down or folded up
before sitting down/standing up. Do not stand on
the footrests!
•
Do
not
move the chair against door thresholds,
edges or other uneven surfaces
•
Only
use the product indoors and on flat, skid-
proof surfaces.
•
Only
move the chair at a moderate walking pace
(with and without patients)
•
Do not lean out of the chair (both in standstill and
while moving). If the swivel castors are in an unfa-
vourable position (pointing inwards), stability of the
chair is limited.
•
The adjustable chair legs must all be set to the
same height. The screws must be tightened.
Caution: Danger of breakage!
•
The chair is
only
suitable for the intended use (see
section 2). Observe the permissible max. body
weight (information on the nameplate)!
•
Never carry or lift the product while a patient is sit-
ting on it.
•
Do not pull or hold on to additionally attached com-
ponents or accessories.
Caution: Danger of pinching or catching!
•
When folding the armrests up or down, do not
reach into the joint guide so that no parts of the
body etc. are trapped.
•
When attaching the seat plate, do not reach be-
tween the seat surface and the frame so that no
body parts are trapped.
•
When folding down the footrests, take care to
avoid trapping any parts.
•
When pulling out and pushing in the toilet bucket,
there is a risk of trapping soft tissue of the patient.
To prevent injuries, the bucket may only be pulled
out or pushed in when no user is sitting in the chair.
Caution: Risk of injury!
•
There is a risk of injury with surface temperatures
> 40 °C. Therefore, do not expose the product to
high temperatures (e.g. sunlight, radiators, hot wa-
ter). Allow the product to cool down before use.
If the product is used by patients with insen-
sitive skin (no temperature perception or
skin damage), a heat check (e.g. touching with the
back of the hand) must be carried out by the nursing
staff.
5. Incident reporting
•
Serious incidents in connection with the product
must be reported immediately to the manufacturer
and BfArM.
BfArM:
▪
Use the reporting functions and provided
forms.
Manufacturer:
6. Warranty
•
For this product the manufacturer grants a war-
ranty of 12 months. Compliance with the general
terms and conditions(
), as
well as the intended use, are a basic prerequisite.
The statutory warranty provisions shall apply.
•
Unauthorised modifications to this product will void
the product’s conformity and the warranty.
6.1. Complaint
•
Please contact us before returning the product.
•
To reduce transport damage, use the original
packaging if possible.