11
a
b
i
Mounting
Mounting: flush and non-flush mountable
For flush mounting in metal or other materials.
These sensors can be mounted close
together (see Fig. 1 and 3) and are specially designed for contact-less detection of solids or
liquids through non-metal containers.
For non-flush mounting in metal or other materials.
When mounting two or more sensors
side by side a space / free zone must be provided (see Fig. 2 and 4). These are particularly
suitable for applications where you need a larger working range to the sensor size.
Flush mountable
Non-flush mountable
Fig. 2
Fig. 1
Diameter “d“
"Zone without
a thread"
Free zone ≥ 3 x d
Mounting / detectable
material
Fig. 4
Fig. 3
Flush mountable
Non-flush mountable
Mounting / detectable
material
EN
Two opposite sensors have to be mounted with a distance of at least 2.2 times the operating
distance (distance “a”).
For non-flush mountable sensors, the zone without a thread has to be mounted with a distance
of at least 1.5 times the operating distance from the damping material (distance “b”).