Typically select “Without lock”, “Fail secure”, or “Fail safe” for North American applications.
PARAMETER
Driving Cycle >
Time delay open >
Drive >
Entrance System >
Control unit >
Locking >
LOCKING
Locking functions 2
Lock type
LOCK TYPE
5 MPV20
6 MPV16
7 Magnet
11 Fail Secure
12 Fail Safe
14 Double
Operation mode >
SERVICE STG
Maintenance >
Functions >
Configure System
Learning System >
Parameter >
Start Delay 0
Closed VRR Error
Closing Force
PARAMETER
Driving Cycle >
Time delay open >
Drive >
Entrance System >
Control Panel >
Locking >
LOCKING
Locking functions 2
Lock type
Start Delay 0
Closed VRR Error
Closing Force
LOCK TYPE
0 Without lock
3 Motor powered
4 Bistable
5 MPV20
6 MPV16
7 Magnet
LOCKING FUNCTION
1 Night locked
2 One-way locked
3 Always locked
“Night locked” is for use with
“Fail-safe” autolocks, and door is
to be locked when the door is
“Locked”. Also see Control Panel /
Display Panel / Keyboard parameter.
PARAMETER
Driving Cycle >
Time delay open >
Drive >
Entrance System >
Control unit >
Locking >
LOCKING
Locking functions 2
Lock type
Start Delay 0
Closed VRR Error 0
Closing Force 0
Start Delay
0
Delay time until
door opens
after unlocking
0=no delay
40=8 second
delay.
Operation mode >
SERVICE STG
Maintenance >
Functions >
Configure System
Learning System >
Parameter >
PARAMETER
Driving Cycle >
Time delay open >
Drive >
Entrance System >
Control Panel >
Locking >
LOCKING
Locking functions 2
Lock type
Start Delay 0
Closed VRR Error 0
Closing Force 0
Closed VRR Error
0 Disabled
1 Enabled
If enabled, after
a restart or
locking problem,
control checks
locking with shor
t
movement.
Closed VRR Error
0 Disabled
1 Enabled
Consult factory before connecting third party electric locks to the lock output of the door control.
When electric locking is enabled, actuation of the control will cause the lock output to immediately
change state, followed by the Start Delay, then the door begins to open. 0=1/2second; 1 thru 40
increases in 0,2 second increments (20 = 4.5 seconds).