Description
3
BAL_PROTECT_full_turn_EN_1V0_REC_102-905401101
13 / 20
Canopy (Option):
Aluminium frame with 4mm thick polycarbonate
transparent infill or grey solid infill, with connecting
brackets to the unit frame in stainless steel AISI 304 grade ( upgradable to
316 grade as option)
Function:
Passage in both directions, electronically controlled.
Mechanism:
Control operation is achieved by an
electromechanical head mechanism. Head damping available as an op-
tional extra.
Security:
Passage through the “dead area” is prevented by stator bars.
Power Supply:
115/230 Vac 50/60Hz
Power Rating:
Standby or Passage 50Va (Alarm Condition 50Va)
* Heater Kit Option add 400W
Logic Voltage:
24Vdc
Power Failure:
In the event of an emergency or isolation of the power supply the full turn
can be configured to Fail- Safe i.e. Rotates freely or Fail-Lock i.e. locks in
the HOME position. Either option is available in one or both directions. (As
standard the full turn is configured bi-directional fail-safe unless requested
during the ordering process) This is configurable on site if required.
Fire Alarm:
Input facility available for 0V contact supplied by others to effect fail state.
Interface:
The mechanism is controlled by means of the LL2001 microprocessor con-
trol logic with the following features:
The basic features of the board are as follows:
– One input for unlocking the Titan-Lite FHT for transit in direction ‘A’;
– One input for unlocking the Titan-Lite FHT for transit in direction ‘B’;
– Two pairs of protected outputs for driving the traffic lights (Red and Green) in directions ‘A’ and
‘B’;
NOTICE
Two pairs of protected outputs can be used for driving the Red and Green lights in direction A
(PL) and B (PR). In this mode the remaining two outputs can be used for indicating availability
of use or for counting passage in either direction.
Two outputs that can be directed to relays with voltage free contacts to provide an interface
with external components;
– One relay output with voltage free contact for alarm signalling;
– Six TTL inputs for optional devices connection;
– Fast acting fuses 5 x 20mm, 2A / 250V;
– RS485 asynchronous serial line; (Protocol available on request)
– Two NPN outputs that can be used to provide an interface with external components.
– Programmable by means of Trimmers;
– Microprocessor reset button;
– One output that can be directed to a relay with voltage free contacts to provide a TECHNICAL
Alarm
– TABELLE
Operating Temperature: 5°C to +50°C 10°C to +50°C (With optional heater Kit)
– Transportation and Storage: -25°C to +55°C
– Note - This Technical Manual is applicable to all variants.
3.5
Alternative options and Accessories
– Alternative finishes and materials.
– ITC (Improper transit control) Detects users entering the unit in the wrong direction ( with Audible
alarm ) Confirms an authorized passage has been completed