Security inspection according EN 16005
2
BAL_S20_EN_1V0_REC_121-006454590
12/ 33
DIN aluminium finishing profiles
Solution:
▪
DIN aluminium finishing pr safety distances
▪
DIN aluminium finishing profiles
See Book B1 „General Information“ Chapter „General Plans“
Example D-STA 32 mm with side screen and cladding
Version DIN aluminium finishing profiles (P1752) Version rubber finishing profiles (P1760)
NOTICE
The version with rubber finishing profiles is not EN 16005 compliant with
respect to the 8 mm distance.
Safety distances
Safety distances must be observed during the opening cycle.
A safety distance Y between secondary closing edge (rear edge of door leaf) and the adjacent parts
of the surroundings must be respected, depending on the distance X between the front part of the
door leaf and the fixed side screen (see Figure a).
In that case, the impact hazard and the hazard concerning crushing of the body are considered to be
not relevant and no more safeguard is required.
For telescopic doorsets, the reference leaf for the measurement is considered to be the one nearest
to the adjacent part of the surroundings.
▪
If
X ≤ 100 mm
then
Y ≥ 200 mm
▪
If
100 mm < X ≤ 150 mm
then
Y ≥ 500 mm
▪
If
X > 150 mm
then
the door leaf opening movement must be safeguarded.
Figure a) Crushing protection
Figure c) Distance from surface of doorset leaf
Safeguards concerning shearing and drawing-in hazards shall be deemed to have been provided at
the danger points during the opening cycle if safety distances shown in Figure b) and Figure d) are
met.
2.3.1