Specifications
4
BAL_Speedgate_slide_EN_1V0_REC_102-905401041
15 / 26
ing on an obstruction. Should the normal wings operation be stopped
by an obstruction, the controlling logic detects an abnormal conditions
and activates a series of operations aimed at protecting the user.
Method of Operation
On receipt of a signal from the access control system, or push button,
the wings will open. (Remain in open position for N/O set up) If an un-
authorised person attempts to tailgate or tries to enter from the oppos-
ite direction, the system detects and closes the unauthorised passage
and activates an alarm. Presence sensing is achieved with 6NO in-
frared sensors for the N/C version and 14NO for the N/O variant.
Power Failure
In the event where isolation of the power supply occurs, the wings re-
main in the current position. Battery Back Up is available as an op-
tional extra to operate the wings to open in a power down scenario
(Fail safe)
Fire Alarm
An input facility is available for voltage free contact (supplied by Oth-
ers) to open the walkway in the event of an emergency.
Location
Indoor, out of rain and water sprays, Speedgate Swing Advanced is
not protected from dangerous effects of water penetration; non direct
sun light; Not along escape routes or obstructing emergency exits, Do
not use in potentially explosive atmospheres.
Interface
Potential free contact provided by either card reader or push button in-
put. Card reader inhibit and reset output signals are available as stand-
ard. The unit has an adjustable time out facility if required, for example;
a “Go” Signal will be cancelled if the passage through the Speedgate is
not completed within a pre-set time i.e. 5-30 seconds