Servicing and maintenance
18 / 26
BAL_Speedgate_slide_EN_1V0_REC_102-905401041
6.2
Routine maintenance
The mechanism should be inspected and cleaned at regular intervals, in order to maintain all com-
ponents correctly & to keep them in good working order. Also to check for signs of wear.
WARNING
To avoid the risk of electric shock, always ensure that the electrical power and batter-
ies are disconnected before inspecting the mechanism.
NOTICE
The following indications refer to an installation where the average number of trans-
its per year is equal to one million.
When used in dusty conditions, increase the inspection intervals.
Lubricants
For the lubrication of parts subject to wear, use Molycote BR2 Plus grease or equivalent grease con-
taining graphite or molybdenum sulphide (MoS2).
Do not grease moving parts unless specifically indicated in this manual. The use of grease can lead
to a build-up of dust that can impair operation of the mechanism.
Components
Annual Checks (Operations to be carried out with the power supply disconnected).
Cables and Connectors (Operations to be carried out with the power supply disconnected).
– Check that the wire connectors are firmly attached.
– Check that the terminals are fully tightened.
– Check that the insulation of the wires is in good condition and that no conductors are exposed.
Electrical Circuits
No general Maintenance is required apart from replacement fuses in the event of a failure.