  Adjust voice level in voice trigger conditions. Setting range is 1-10.  

!

4. VOX Silence 

  Adjust silent time to terminate recording in voice trigger conditions. Setting Range is 

5-99 sec 

!

5. Max REC Duration  

Set maximum recording time for single call. Setting range is 10 min ~

 

 

!

6. Min REC Duration  

Set minimum recording time for single call. Setting range is 5 sec ~ 

 

!

7 .Loop Recording 

  

(1)Enable 

When the SD card capacity is insufficient, it will delete the old audio files 

automatically and keep recording.  

  (2)Disable 

When the SD card capacity is insufficient, it will not record any more.  

!

8. Storage Capacity Alert 

  The LCD remaining recordable time symbol will blink when storage capacity is lower 

than setting. Setting range is 5-99 hours. 

!

9. Play Announcement 

  Enable / Disable to play announcement that the call is recorded to caller 

!

10. Off Hook Voltage 

 

  The system will record the call automatically when the line voltage is lower 

than setting. Setting range is 15~30(V). 

11. Call Out Delay Time 

   

The system will record calls after setting delay time

.

 Setting range is 0~20 

sec 

!!

!!

!

(B) .System Setup 

!

SR100 Operate Instruction 

 

!

9

Summary of Contents for SR100

Page 1: ... SR100 Digital Telephone Recorder Operate Instruction Version1 0 0 INDEX ...

Page 2: ...1 INTRODUCTION This device is a single line voice logger It can record all the calls over the phone including Caller ID date time and elapse The table of contents is empty because you aren t using the paragraph styles set to appear in it SR100 Operate Instruction 2 ...

Page 3: ...port 4PHONE port 5Handset Line 6Volume 7Volume 8Handset 9SOURCE PHONE 10SOURCE MICROPHONE 11SET 15Fast Forward 16Recording 17Fast Reverse 18Pause 19Play 20Stop 21Page Down 22Page Up 23Back 24Records 25SD Card SR100 Operate Instruction 3 ...

Page 4: ... Requirement 1 Windows7 Vista XP 2000 2 Above Pentium 400 MHz CPU 3 256MB RAM 4 1GB HDD capacity 5 USB interface 5 Connection 1 Analog line connection a Switch the SOURCE to PHONE b Co line to LINE port c Phone to PHONE port will be shown on the LCD See P 9 for set up SR100 Operate Instruction 4 ...

Page 5: ...hone Connection Handset a Switch SOURCE to PHONE b Connect handset line to LINE c Connect handset to PHONE will be shown on the LCD Voice trigger setup is necessary See Page 9 for set up SR100 Operate Instruction 5 ...

Page 6: ... 3 Microphone connection Environmental Record a Switch SOURCE to MIC will be shown on LCD See Page 8 for set up Remark See Page 11 for initial Time Date set up SR100 Operate Instruction 6 ...

Page 7: ...ecording mode Auto Auto recording mode Manual Manual recording mode Trigger Voice Trigger mode Loop recording mode 10H Recording time of remaining capacity Time System Time B Talk Mode Type Incoming Outgoing Elapse Talking time Phone number Incoming Outgoing phone number 7 Setup A Recording Parameter SR100 Operate Instruction 7 ...

Page 8: ... higher than settings it starts recording automatically 2 Auto Manual Rec You can set channel recording conditions 1 Manual Recording Press RECORD to start STOP to terminate 2 Automatic Recording When line voltage is lower than settings it starts recording automatically 3 Voice Trigger When voice level is higher than settings it starts recording automatically 3 VOX Trig Level SR100 Operate Instruc...

Page 9: ...dio files automatically and keep recording 2 Disable When the SD card capacity is insufficient it will not record any more 8 Storage Capacity Alert The LCD remaining recordable time symbol will blink when storage capacity is lower than setting Setting range is 5 99 hours 9 Play Announcement Enable Disable to play announcement that the call is recorded to caller 10 Off Hook Voltage The system will ...

Page 10: ...System date display format setup 5 Time synchronization with Caller ID Synchronize the time with FSK Caller ID 6 Language You can choose Traditional Chinese Simple Chinese or English as system language 7 LCD Contrast Adjust the contrast of LCD display the higher the brighter Range 1 6 SR100 Operate Instruction 10 ...

Page 11: ...s 10 Default setting Reset to factory default 8 Record A Records Display Description 1 Record Type I Incoming call O Outgoing call N MIC T Voice Trigger A Answering machine 2 Date Time Display date and time of audio files 3 Recording Length Display the length of audio files 4 Symbol indicates audio files otherwise CDR only SR100 Operate Instruction 11 ...

Page 12: ...dio files 2 Flag Mark important audio files 3 Remove Flag Remove mark on audio files 4 Delete Delete selected audio files or CDR 1 Delete audio files and keep the CDR 2 Delete both audio files and CDR 5 Search by Time Search audio files by time 6 Search by number Search audio files by incoming outgoing numbers C Play Audio files SR100 Operate Instruction 12 ...

Page 13: ...e number and process will be shown on LCD You can delete or flag the audio file directly D Searching Option 1 All Search all records in SD card 2 Incoming Search all incoming calls including missed calls SR100 Operate Instruction 13 ...

Page 14: ...Search all audio files from MIC 7 Flag Search marked audio files 8 Trig Search voice triggered audio files 9 Answering Search answering machine messages audio files You can search specified audio files by operating search functions 8 Service Guarantee One 1 Year Limited Warranty Limited Warranty SR100 Operate Instruction 14 ...

Page 15: ... instruction USB cable telephone cord and software CD b to damage caused by accident abnormal voltage abuse misuse liquid contact fire earthquake or other external causes c to a product or part that has been modified to alter functionality or capability without the written permission d to damage caused by customer relocation or falling or d to defects caused by normal wear and tear or otherwise du...

Reviews: