Ceiling Mount LED
Exit Sign
Installation Instructions p.1
Red Arrow Trading
Elsworth House, Herries Road South
Sheffield, S6 1QS
T:
0800 195 0006
F:
0870 043 3946
E:
sales@redarrowtrading.com
www.redarrowtrading.com
For models: HTLEDCM
Specification
•
Ceiling Mount LED Exit Sign
•
240V
•
2W
•
13pcs of SMD 2835 White LEDs
•
40-50 Lumen output
•
2.4V 900mAh Ni-Cd Battery
•
1 Year guarantee
•
IP20
This installation must be carried out by an electrician.
Please read these instructions carefully before installation.
Leave a copy for the user/maintenance engineer for future reference.
Structure Diagram
1.
Indication light for charging.
2.
Indication light for main function and error.
3.
Indication light for mains power.
4.
Test switch.
Terminal Block Instruction
L.
AC220V connect the live wire
E.
Connect the earth wire
N.
AC220V neutral wire
Brief Introduction
This product is suitable for use in buildings such as hotels,
restaurants, supermarkets and other public buildings with fire
protection systems. It can be used to indicate directions for an
exit or passage as well as to indicate storing locations of fire
safety products and dangerous materials. It can also be used
for emergency evacuation or fire protection.
Functions and Features
This product is made with high quality LEDs, which features
clear soft light, less power consumption and long working
life expectancy. As a result, it is regarded as an upgraded
replacement of normal exit lights with fluorescent tubes. It
is a continuous working emergency evacuation indication
light, assemblied with fully sealed nickel cadmium battery
and good electronic components. Its circuit has a function of
over charge and over discharge protection which can protect
the battery from damage and extend its lifetime greatly by
preventing the voltage from dropping to the limited value
when discharging.
Operation
1.
When this product is connected to the mains power supply,
the green mains indicator and the red charging indicator
automatically turn on. When the light is fully charged, the
luminaire will light normally, while the red indicator
automatically turns off. Press the test switch, the luminaire
will flash for a short time and will remain on if it is
working correctly.
2.
When the AC power is suddenly shutdown, the luminaire
remains on. Press the test switch for about one second, the
luminaire turns off. Press the test switch for half second,
the luminaire turns on.