1. 

Near appliances or areas where normal combustion regularly occurs (kitchens, near furnaces, hot water heaters). Use 

    specialised smoke alarm with unwanted alarm control for these areas. 

2. 

In areas with high humidity, like bathrooms or areas near dishwashers or washing machines. Install at least 10 feet 

    away from these areas. 

3. 

Near air returns or heating and cooling supply vents. Install at least 3 feet away from these areas. The air could blow 

    smoke away from the detector, interrupting its alarm. 

4. 

In rooms where temperatures may fall below 4°C or rise above 38°C. 

5. 

In external dusty, dirty, or insect-infested areas where loose particles interfere with smoke alarm operation.

WARNING: 

Incorrect orientation will result in a decrease in operational effecitiveness. 

How To Install This Smoke Alarm

DANGER: ELECTRICAL SHOCK HAZARD.

Turn off power at the main fuse box or circuit breaker by removing the fuse or switching the circuit breaker to the OFF 

position. 

WARNING: 

This smoke alarm is mains powered and requires wiring by a qualified electrician in accordance with the 

current IEE Regulations for Electrical Installations (BS7671). 

The circuit used to power the smoke alarm must be a dedicated permanent supply that cannot be switched off accidentally 

by the normal user. Before installing, ensure the electrical supply is isolated. 

1. 

From back of smoke alarm, remove the mounting plate by turning it counterclockwise. (To later engage tamper-resist 

    feature, twist out and set aside one of the pins molded into plate. Both pins are exactly the same).

2. 

Gently pull household wires through center hole of plate.  

3. 

Secure plate to ceiling or wall with mounting screws.

4. 

With a small wire connector, connect the brown wire from connector plug to brown household wire. 

5. 

Connect blue wire from connector plug to blue houeshold wire. 

6. 

If interconnection is desired, connect yellow wire from connector to interconnect wire between smoke alarms. 

See Section: Interconnecting Smoke Alarms
NOTE: 

If this will be used as a single-station smoke alarm, cover yellow wire with electrical tape and tuck it into junction 

box.  

7. 

Lift open battery pocket door. 

8. 

Connect new 9V battery to battery connector inside battery pocket. Be sure battery is securely connected. Smoke 

    alarm may beep briefly when battery is installed. 

9. 

Close battery pocket door, snapping it into place. 

10. 

Attach connector plug to pins on back of smoke alarm. Plug will only fit one way and will snap into place. 

11. 

Gently tug connector to be sure it is attached securely.

Mounting slots
Mounting bracket

Screw

9V Battery

Summary of Contents for SMAS-P

Page 1: ... not use any other test method Test smoke alarm weekly to ensure proper operation 3 DO NOT cut off AC power supply or remove or disconnect backup battery to quiet unwanted alarms This will remove your protection Open windows or fan the air around smoke alarm to silence it 4 Observe and follow all local and national electrical and building codes for installation 5 This smoke alarm is designed to be...

Page 2: ...ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area If a bedroom area hallway is more than 30 feet long install a smoke alarm at each end If there is a basement Install a smoke alarm on the basement ceiling at the bottom of the stairwell SINGLE STORY RESIDENCE APARTMENT MOBILE HOME Typical Multi story or split level home Install a smoke alarm on the ceiling o...

Page 3: ... a dedicated permanent supply that cannot be switched off accidentally by the normal user Before installing ensure the electrical supply is isolated 1 From back of smoke alarm remove the mounting plate by turning it counterclockwise To later engage tamper resist feature twist out and set aside one of the pins molded into plate Both pins are exactly the same 2 Gently pull household wires through ce...

Page 4: ...once a minute to indicate the battery is healthy and the unit is operating properly If smoke is detected the unit will emit a load pulsating alarm and a RED indicator light LED will be flashing quickly until the air is clear Testing The Smoke Alarm 1 Test each smoke alarm to be sure it is installed correctly and operating properly 2 The push to test button accurately tests functions Do not use an ...

Page 5: ...res one standard 9V battery The following batteries are acceptable as replacements Golden Power 6F22 Megaton 6F22 New Leader 6F22 Gold Peak 1604 Eveready 522 1222 Golden Power G6F22 Golden Power GL6F22A Cleaning Clean the smoke alarm at least once a month to remove dust dirt or debris Using the soft brush or wand attachment to a vacuum cleaner vacuum all sides and cover of smoke alarm Be sure all ...

Page 6: ...tently or when residents are cooking taking showers etc 1 Clean smoke alarm See cleaning in the maintenance and cleaning section 2 Move the smoke alarm to a new location See Smoke Alarm Placement The alarm sounds different to what i m used to It starts and stops The alarm is operating correctly This alarm features the internationally recognised horn signal for evacuation The horn pattern is 3 shor...