8
Owner’s Manual:
1400 & 1410
1787021 REV H
ECO 16-0082
Feb 2021
Air & Explosion
www.radiaproducts.com (PHONE) 800-221-1083 | (INTL) +1-763-533-2969 | (FAX) 763-533-0015
IMPORTANT: Before attempting to operate the
machine:
1. Remove all packing material from the unit.
2. Remove all packing material from the base.
1. Attach both base castings
(A)
to the mixer, using
the four carriage bolt
s
(B)
,
washers
(C)
,
and nuts
(D)
provided.
2. Install a rubber foot
(E)
into each end of the
springs
(F)
.
3. Lift one side of the mixer. Insert a spring and foot
assembly into the depression in the bottom of each
corner of the base
(G)
.
4. Lift the other side of the mixer, and repeat the
third step.
NOTE:
Be sure that the machine and base are placed
on a flat, stable countertop surface.
(A)
(D)
(C)
(B)
(E)
(E)
(G)
(F)
NOT FOR USE WITH 1400-X1
3. Assemble and Test
3. Assemble and Test
3.1 Prepare for Use
3.1 Prepare for Use
3.2 Assemble the Countertop
3.2 Assemble the Countertop
Base
Base
(See Section 8.10)
(See Section 8.10)
Assembly and Test, Continued..
1. Wipe bottom of pedestal base with alcohol, acetone,
or equivalent.
2. Sweep floor and wipe with alcohol, acetone, or
equivalent.
3. Adhere VHB pads (4) to bottom of pedestal base as
shown above.
4. Place pedestal base on clean floor.
3.3 Assemble the Pedestal Base
3.3 Assemble the Pedestal Base
(See Section 8.11)
NOTE:
Moving Pedestal Base: If it becomes
necessary to move the machine to a different
location, release the bond between the floor and
pedestal base by inserting a wall scraper between
them. Contact Red Devil Equipment Co. / Radia for
replacement VHB pads.