PROBLEM
CAUSE
REMEDY
Machine won’t run
Not connected to power source Connect to power source
Building circuit breaker or fuse
blown
Reset breaker or replace fuse
Machine door does not make
contact with door limit switch
Readjust switch to make contact with
door switch screw when door is closed
Motor thermal protector acti-
vated
Allow to cool, then restart
Machine circuit breaker tripped
Reset by pressing circuit breaker back
in
Faulty Motor
Contact Red Devil Equipment Co.
Customer Care
Emergency E-STOP pushbutton
is activated
Turn switch knob 1/4-turn clockwise to
disengage
Faulty controller
Contact Red Devil Equipment Co.
Customer Care
Door switch is faulty or needs
adjustment
Adjust the door switch. For replacement,
contact Red Devil Equipment Co.
Customer Care.
Worn, damaged, or loose drive
belt
Unplug power cord, open mixer door,
and visually inspect the drive belt
Excessive Vibration
Pail damaged
Fix or replace pail
Can not properly seated
Reset can into holder
Feet are not level
Adjust and level feet
Machine doesn’t shut off at
end of mixing cycle
Faulty controller
Contact Red Devil Equipment Co.
Customer Care
Machine doesn’t shut off
when door is opened
Faulty door limit switch
Contact Red Devil Equipment Co.
Customer Care
Increasing mechanical noise Bearings worn or damaged
Contact Red Devil Equipment Co.
Customer Care
Disconnect the machine from its power source before servicing .