Note: When GENLOCK is selected as the sensor shutter reference, shutter start timing (SHUTTER
PHASE) may still be adjusted. HD-SDI monitor outputs will automatically sync to the external
GENLOCK signal as soon as it is detected, there is no need to enable this function. Sensor shutter
sync to GENLOCK is only supported with HD-SDI.
View into camera SYNC (Video Sync) Interface connector
Mating Connector: FGG.00.304.CLAD27Z
PIN
SIGNAL
DESCRIPTION
1
GROUND
Common Ground
2
SS/GPI
Shutter Sync / GPI Trigger Input
3
TIMECODE
SMPTE unbalanced timecode Input
4
GENLOCK
RS170A Tri-Level Sync Input
NOTE: The Camera Brain’s Shutter Sync / GPI Trigger uses a 3.3 V Schmitt trigger (5 V tolerant). It
is not a switch closure circuit. Therefore, it requires current supplied by the trigger source. Both
edges of the input signal may be used as a trigger.
For example, when GPI trigger is used for Record Start / Stop.
•
Start Record:
On Ground to 3.3 V transition
•
During Record:
Hold at 3.3 V
•
Stop Record:
On 3.3 V to Ground transition
•
During Stop:
Hold at Ground