7-CONTROL PANEL ASSEMBLY FOR LEFT OPENING
•
remove the plate “N” on the back panel of the stove by taking out the two screws “x”
•
disconnect the cable “C” connected to the panel, from the electronic board of the stove and remove it from the hole
•
on the back panel the cable ”C” then remains secured to the plate “M” (see the image below)
•
remove the knockout hole “s” in the left part of the stove
back panel
•
pass the free end of the cable “C” through the hole “s” and
connect it to the board
•
secure the plate “M” as indicated on the following page
•
rotate and secure the piece “N” in the new position, on the
left, above the cable “C”
M
C
CONNECTION TO THE CONTROL
PANEL
BOARD CONNECTION