S
U
V
4
3
2
1
6
5
42
10-MULTIAIR DUCTING
Multiair Ducting
Multiair stoves can channel the air into other rooms through connection with the accessory pipes to the rear standard “
S
” pipe. The
recommended maximum duct length is 8 metres per fan. It is advisable to set up ducts of similar length to distribute the hot air evenly
in the various rooms.
The output air pipe can reach very high temperatures, even around 150°C: therefore, it must be adequately
insulated with suitable material, especially points that could come in contact with flammable surfaces or parts that
are affected by heat (e.g. change in shades, wiring ducts, plasterboard, etc.). Moreover, persons and animals must
be protected from accidental or intentional contact. In any case, comply with the regulations and laws in force in the
region where the product is installed.
It is recommended to insulate the entire length of the pipe in order to reduce dispersion and increase heat output
in the room.
If you do not wish to channel the air, the hot air may be let out through the rear “
V
” vent without connecting any pipe.
The “
V
” vent and the “
U
” clamp used for fastening are found in a plastic bag inside the stove firebox.
1 - ROOM FLOOR
2 - ROOM CEILING
3 - WALL
4 - STOVE
5 - HOT AIR DUCTING
6 - INSULATION