1
z
6-DIGIT, 0.56" (14.2 mm) HIGH LED DISPLAY (APLR)
z
CRYSTAL-CONTROLLED TIME-BASE PROGRAMMABLE UP TO
32.764 SECONDS PROVIDES DIRECT-READING FOR ANY RATE
UNITS
z
0.02% ACCURACY
z
PROGRAMMABLE DECIMAL POINTS
z
FREQUENCY DOUBLING
z
PROGRAMMABLE INPUT CIRCUIT, ACCEPTS OUTPUTS FROM
A WIDE VARIETY OF SENSORS
z
LEADING ZERO BLANKING
z
POWER-UP SELF-TEST
z
NEMA 4/IP65 SEALED FRONT METAL BEZEL
DESCRIPTION
The Apollo Time Base Rate Indicators (Model APLR) and Module (Model
PBLR), provide the versatility and flexibility needed to accommodate virtually
any rate measuring need. Based on Micro-processor technology, this unit
represents the optimum in cost/performance ratio.
This unit has the ability to scale for direct readout in terms of the units being
measured. Whether a machine produces bottles, cloth, wire, or beverage mix,
operation is enhanced when the rate readout is expressed directly in
bottles/min., feet/min., gallons/hour, or whatever units are needed in plant
operations. The APLR/PBLR can provide this capability through its settable
time base, programmable decimal points, and frequency doubling functions.
The APLR/PBLR can also accommodate magnetic pickups, as well as logic
(sourcing output)
sensors and NPN open collector
(sinking output)
sensors.
This unit also has a self-test feature, which checks all the micro-processor
and display driver circuitry after power-up
(if enabled)
. This self-test also can
be used to test the time base select DIP switches and decimal point select DIP
switches, to make certain all switches are functioning properly.
Power and input connections are made via a removable terminal block,
located at the rear of the unit. Each terminal can accept one #14 AWG wire. DIP
switches at the side of the unit are used to program the input configuration.
The Apollo Rate Indicator has a sealed metal die-cast bezel which meets
NEMA 4/IP65 specifications for wash-down and/or dust, when properly
installed. Two mounting clips are provided for easy installation. The Time Base
Rate Indicator uses a 6-digit, 0.56" (14.2 mm) high LED display, which is
readable to 23 feet (7 M).
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
SPECIFICATIONS
1.
DISPLAY:
6-Digit, 0.56" (14.2 mm) high LED display. (APLR)
2.
POWER REQUIREMENTS:
APLR
AC Operation
: Available in two voltages.
115 VAC, ±10%, 50/60 Hz, 14 VA or
230 VAC, ±10%, 50/60 Hz, 14 VA
DC Operation
:
24 VDC, 10% @ 0.6 A max.
Note: All available units can be powered at Terminal #3 from a 11 to 14
VDC, 0.6 A max. power supply.
PBLR
AC Operation
: Switch selected via the LDD power supply board,
115/230 (+/-10%), 50/60 Hz, 10 VA for 4-digit, 15 VA for 6 digit
(including LDD)
.
3.
SENSOR POWER:
+12 VDC, ±25% @ 100 mA max.
4.
MAXIMUM OPERATING FREQUENCY:
10 KHz, 50% duty cycle.
10,000 cps with min. pulse width
“ON”
and
“OFF”
times of 50 µsec.
5.
TIME BASE SELECTION RANGE:
0.004 to 32.764 seconds.
6.
ACCURACY:
0.02%
7.
MAXIMUM INPUT VOLTAGE AND CURRENT:
When the
“SIG. IN”
(Terminal 5) is driven from external signal voltages, max. voltage swing is
±50 V peak. Input voltage can be dropped by an external series resistance that
limits input current to ±5 mA.
(These ratings are for S3 “OFF”.)
MODELS APLR - APOLLO 6-DIGIT RATE INDICATOR [TIME BASE] AND
PBLR - 4/6 DIGIT MODULE FOR USE WITH THE LARGE DIGIT DISPLAY (LDD)
DIMENSIONS In inches (mm)
Note: Recommended minimum clearance (behind the panel) for
mounting clip installation is 2.1" (53.4) H x 5.5" (140) W.
PANEL CUT-OUT
CAUTION: Risk of Danger.
Read complete instructions prior to
installation and operation of the unit.
CAUTION: Risk of electric shock.
Bulletin No. APLR-N
Drawing No. LP0118
Released 6/06